ASTM International - ASTM C140-13
Standard Test Methods for Sampling and Testing Concrete Masonry Units and Related Units
Organization: | ASTM International |
Publication Date: | 15 March 2013 |
Status: | inactive |
Page Count: | 22 |
ICS Code (Concrete and concrete products): | 91.100.30 |
significance And Use:
4.1 These test methods provide general testing requirements for application to a broad range of concrete products. Those general testing requirements are included in the body of this... View More
scope:
1.1 These test methods provide various testing procedures commonly used for evaluating characteristics of concrete masonry units and related concrete units. Methods are provided for sampling, measurement of dimensions, compressive strength, absorption, unit weight (density), moisture content, flexural load, and ballast weight. Not all methods are applicable to all unit types, however.
1.2 Specific testing and reporting procedures are included in annexes to these test methods for the following specific unit types:
Annex A1-Concrete masonry units (Specifications
C90, C129) |
Annex A2-Concrete and calcium silicate brick (Specifications C55, C73, C1634) |
Annex A3-Segmental retaining wall units (Specification
C1372) |
Annex A4-Concrete interlocking paving units (Specification C936/C936M) |
Annex A5-Concrete grid paving units (Specification
C1319) |
Annex A6-Concrete roof pavers (Specification
C1491) |
Annex A7-Dry-cast articulating concrete block (Specification D6684) |
1.3 The test procedures included in these test methods are also applicable to other types of units not referenced in these test methods, but specific testing and reporting requirements for those units are not included.
1.4 These test methods include the following sections:
Section | |
Scope | 1 |
Referenced Documents | 2 |
Terminology | 3 |
Significance and Use | 4 |
Sampling | 5 |
Measurement of Dimensions | 6 |
Compressive Strength | 7 |
Absorption | 8 |
Calculations | 9 |
Report | 10 |
Keywords | 11 |
Annexes-Test Procedures | |
Concrete Masonry Units | Annex A1 |
Concrete and Calcium Silicate Brick | Annex A2 |
Segmental Retaining Wall Units | Annex A3 |
Concrete Interlocking Paving Units | Annex A4 |
Concrete Grid Paving Units | Annex A5 |
Concrete Roof Pavers | Annex A6 |
Dry-Cast Articulating Concrete Block | Annex A7 |
Determining Plate Thickness Requirements for Compression Testing | Annex A8 |
Worksheet and Test Report for Concrete Masonry Units | Appendix X1 |
Note 1-The testing laboratory performing these test methods should be evaluated in accordance with Practice C1093.
1.5 The values stated in inch-pound units are to be regarded as the standard, except in Annex A4, where either SI units or inch-pound units are to be regarded separately as standard. The values given in parentheses throughout are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.