1.1 This specification pertains to the criteria and tests to be used for determining whether a(n) organic or inorganic processing addition, when used in the recommended amount at the option of the cement producer in the manufacture of hydraulic cements, meets the requirements as prescribed by...
This specification covers three strength grades of finely ground granulated blast-furnace slag (Grades 80, 100, and 120) for use as a cementitious material in concrete and mortars. The slag shall contain no additions and shall conform to the sulfide sulfur and sulfate chemical composition...
1.1 This test method is suitable for both field and laboratory use to obtain a permanent record of concrete surface profile using replica putty and to determine the depth of that surface profile. Note 1: The procedure in this standard was developed for concrete substrates but may be appropriate for...
1.1 This test method covers determination of the air content of freshly mixed concrete from observation of the change in volume of concrete with a change in pressure. 1.2 This test method is intended for use with concretes and mortars made with relatively dense aggregates for which the aggregate...
1.1 This guide provides information on performance factors such as movement, construction tolerances, and other effects that should be accounted for to properly establish sealant joint size. It also provides procedures to assist in calculating and determining the required width of a sealant joint...
This specification covers reinforced concrete culvert, storm drain, and sewer pipe. The pipe manufactured with this specification shall be of five classes: Class I, Class II, Class III, Class IV, and Class V. The strength requirements for each class are specified. The reinforced concrete shall...
This specification covers reinforced concrete culvert, storm drain, and sewer pipe. The pipe manufactured with this specification shall be of five classes: Class I, Class II, Class III, Class IV, and Class V. The strength requirements for each class are specified. The reinforced concrete shall...
QUALIFIED PRODUCT LIST OF PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION MIL-A-22262 Abrasive Blasting Media Ship Hull Blast Cleaning This list has been prepared for use by or for the Government in the acquisition of products covered by the subject specification and such listing...
1.1 This test method uses a pH meter to measure the pH of as-received granular material that represents what will be used in the field for embankments, subgrades, and retaining wall backfill applications. The principal use of the test method is to supplement soil resistivity measurements to...
1.1 This practice covers non-abrasive surface cleaning of architectural sandstone to remove grease, dirt, loose material, and surface deposits such as soot, fly ash, hydrocarbon residues, and algae and other biological growth in preparation for the application of water repellent coatings....
4.1 The appearance of the various degrees of dry and wet abrasive blast cleaning, hand and power tool cleaning, and water jetting are influenced by the initial rust grades of the steel being cleaned and/or the type and condition of the coating on the existing steel. The standards and guides...
Scope. This specification describes the requirements and verification methods for the following item: IGNITER, TIME BLASTING FUSE: with shock tube capability, M81.
5.1 The standard size designations listed in this practice are provided so that the design team, consumer, and the producer have a common reference in sizing stone materials used in erosion control. The design team should assign a materials survey, and rock quality testing series to determine which...
1.1 This practice covers the evaluation of rock to be used for erosion control. The complexity and extent of this evaluation will be governed by the size and design requirements of the individual project, the quantity and quality of rock required, and the potential risk for property damage or loss...
1.1 This practice covers the evaluation, selection, and application of techniques to establish an examination scheme for use by forensic explosives examiners to identify residues from low and high explosives. A foundation for the consistent approach to the analysis of visible and non-visible...
1.1 This practice covers the evaluation, selection, and application of techniques to establish an examination scheme for use by forensic explosives examiners to identify residues from low and high explosives. A foundation for the consistent approach to the analysis of visible and non-visible...
This specification covers iron-nickel-chromium
5.1 The thermal expansion under load and the 20 to 50 h creep properties of a refractory are useful in characterizing the load-bearing capacity of a refractory that is uniformly heated. Directly applicable examples are blast furnace stoves and glass furnace checkers.
This specification covers standard requirements for pipe piles with protective fusion-bonded epoxy powder coating applied by the electrostatic spray, flocking, or fluidized bed process. The surfaces of steel pipe piles to be coated shall be precleaned, as required. Steel surfaces shall be cleaned...
603350-000020-000890