Introduction A camera crane is safe if used properly. However, improper use, assembly, and disassembly can cause property damage, serious bodily injury and even death. This handbook of safe practices, procedures and conditions coupled with common sense, good judgment, and proper evaluation...
1.1 This test method is intended for remotely operated ground robots operating in complex, unstructured, and often hazardous environments. It specifies the apparatuses, procedures, and performance metrics necessary to measure the capability of a robot to dexterously inspect objects of interest in...
1.1 This practice provides: 1.1.1 Recommendations for the design and integration of an area scan camera system (referred to as "camera system") into a laser powder bed fusion (PBF-LB/M) machine to assess the health condition of the scanner protective window (SPW), 1.1.2...
1.1 This guide covers the evaluation, qualification, and quantification of digital neutron images. These images can be acquired by many methods, including: neutron sensitive imaging plates (Computed Radiography - CR), Digital Detector Arrays - DDA's (amorphous silicon, CMOS, CCD, etc.),...
4.1 The design of a photovoltaic module or system intended to provide safe conversion of the sun's radiant energy into useful electricity must take into consideration the possibility of partial shadowing of the module(s) during operation. This test method describes a procedure for verifying that...
1.1 This practice covers a technique for measuring the groove or void area of a tire tread pattern. The void area is measured on the inked impression of a tire tread statically loaded against heavyweight paper on a load platen. 1.2 This procedure is intended to serve as a reference practice for...
5.1 Air permits from regulatory agencies often require measurements of opacity from stationary air pollution point sources in the outdoor ambient environment. Opacity has been visually measured by certified smoke readers in accordance with USEPA (USEPA Method 9). DCOT is also a method to determine...
The scope of this document is to provide the design specifications/requi
1.1 This test method is intended for remotely operated ground robots operating in complex, unstructured, and often hazardous environments. It specifies the apparatuses, procedures, and performance metrics necessary to measure the mission endurance of a robot while traversing complex terrains in the...
1.1 This test method covers the determination of microplastic particle size distribution, shape characterization, and number concentration (particle counts) in sample extracts containing particles between 5?μm and 100?μm. Light is transmitted through a flow cell containing particles in liquid...
1.1 This test method covers the determination of microplastic particle size distribution, shape characterization, and number concentration (particle counts) in sample extracts containing particles between 5?μm and 100?μm. Light is transmitted through a flow cell containing particles in liquid...
This document describes a practical system for a user to determine observer-to-aircraft
1.1 This practice describes a means to record the exoskeleton configuration when testing. This practice provides a method for recording exoskeleton hardware and software control parameters. 1.2 This practice: contextualizes the exoskeleton configuration during a test, including the identification...
5.1 The color displayed on a VDU is an important aspect of the reproduction of colored images. The VDU is often used as the design, edit, and approval medium. Images are placed into the computer by some sort of capture device, such as a camera or scanner, modified by the computer operator,...
This document specifies requirements and test methods for intraoral cameras used in dentistry on patients for pictorial representation of oral cavities in order to support diagnosis and facilitate patient information. It specifies requirements, test methods, instructions for use and marking....
1.1 This guide provides information and criteria for the selection of camera remote sensing systems that are vessel-mounted for the detection of oil on water. 1.2 This guide applies to the detection of oil-on-water involving cameras of IR, visible, ultra-violet, or night vision types....
This document specifies requirements and test methods for intraoral cameras used in dentistry on patients for pictorial representation of oral cavities in order to support diagnosis and facilitate patient information. It specifies requirements, test methods, instructions for use and marking....
This SAE Recommended Practice provides test protocols with performance requirements for camera monitor systems (CMSs) to replace existing statutorily required inside and outside rear-view mirrors for U.S. market road vehicles. This practice expands specific technical content while retaining...
1.1 This practice covers the requirements for inspection and acceptance of installed reinforced concrete pipe by either person-entry, or remote inspection as shown in Figs. 1 and 2, respectively. FIG. 1 Person Entry Inspection FIG. 2 Remote Inspection Camera 1.2 The scope of this...
1.1 This practice covers the procedure for the post installation verification and acceptance of buried pipe deformation using a visible rotating laser light diode(s), a pipeline and conduit inspection analog or digital CCTV camera system and image processing software. The combination CCTV...