4.1 Use-This guide is intended for use on a voluntary basis by parties who wish to obtain a limited survey of commercial real estate to assess for readily observable moisture affected materials and physical deficiencies conducive to elevated moisture as part of a commercial real estate transaction...
4.1 Use-This guide is intended for use on a voluntary basis by parties who wish to obtain a limited survey of commercial real estate to assess for readily observable moisture affected materials and physical deficiencies conducive to elevated moisture as part of a commercial real estate transaction...
5.1 This test method is a standard procedure for determining the resistance to water penetration during rapid cyclic pulses of dynamic air pressure differences. The air-pressure differences acting across a building envelope vary greatly. These factors should be fully considered prior to specifying...
1.1 This specification covers the design, material, and minimum performance requirements of resilient connectors used for connections between reinforced concrete structures conforming to Specifications C478 and C913 to corrugated steel drainage pipe conforming to Specifications A760 or A762....
1.1 This test method describes a standard procedure for determining the ability of masonry wall drainage systems to collect water that penetrates the exterior masonry wythe during rainstorms and to direct this water back to the exterior surface of the wall. 1.2 This test method is applicable...
1.1 This specification covers special hubless cast iron soil pipe fittings for use in a one-pipe combination vent and waste stack unvented for gravity flow applications. It establishes standards covering material, manufacture, mechanical and chemical properties, dimensions, coating, test methods,...
1.1 This practice covers the sizes and quality of rock to fill gabions and mattresses. 1.2 This practice does not cover the sizes and quality of rock for other erosion control uses such as riprap or drainage. 1.3 This practice does not cover the material properties or construction of gabions...
1.1 This specification covers cast iron soil closet flanges for use in gravity flow plumbing drain, waste, and vent sanitary applications. It establishes standards covering material, manufacture, mechanical and chemical properties, coating, test methods, inspection, certification, product markings,...
1.1 This specification covers the referee test methods for evaluating the performance characteristics of a single-use ureteral stent with retaining means at both ends, during short-term use for drainage of urine from the kidney to the bladder. These stents are typically available in...
4.1 This practice defines a procedure that ensures reasonably consistent preparation of specimens for product testing and evaluation. 4.2 This practice can be used in the laboratories of producers, users, and general interest parties for research and development or quality control work. It is...
1.1 This practice covers requirements for the evaluation and specification of implantable shunts as related to resistance to flow, direction of flow, materials, radiopacity, mechanical properties, finish, sterility, and labeling of shunt assemblies. 1.2 Devices to which this practice is applicable...
1.1 This test method presents a procedure for determining the thermal conductivity (?) of soil and rock using a transient heat method. This test method is applicable for both intact specimens of soil and rock and reconstituted soil specimens, and is effective in the lab and in the field. This test...
1.1 This test method presents a procedure for determining the thermal conductivity (?) of soil and rock using a transient heat method. This test method is applicable for both intact specimens of soil and rock and reconstituted soil specimens, and is effective in the lab and in the field. This test...
1.1 This test method is used to determine the potential for, and relative degree of, biological growth which can accumulate on geotextile, drainage geocomposites, or geotextile/soil filters. 1.2 This test method uses the measurement of flow rates over an extended period of time to determine...
4.1 The information provided in this standard guide is intended for use by designers and specifiers of siphonic roof drainage systems and their related components. Specifically, this guide addresses the use and limitations of plastic pipe and fittings in siphonic roof drainage systems...
1.1 This specification covers the manufacture and purchase requirements of products used for the assembly and construction of circular vertical precast reinforced concrete manholes and structures used in sewer, drainage, and water works. 1.2 Part I, Sections 1 - 11, of this specification...
1.1 This practice covers the requirements for inspection and acceptance of installed reinforced concrete pipe by either person-entry, or remote inspection as shown in Figs. 1 and 2, respectively. FIG. 1 Person Entry Inspection FIG. 2 Remote Inspection Camera 1.2 The scope of this specification is...
1.1 This guide presents a guideline specifying a drainage geocomposite product; it specifically provides recommendations to determine the allowable flow rate of a candidate drainage geocomposite. The resulting value is then compared to a required (or design) flow rate for a...
1.1 This guide describes design, specification, selection, installation, and inspection of new building wall systems, exterior deck and stair components, doors, windows, penetrations and sealant joints of wood and metal frame buildings, typically four stories or less, to minimize water intrusion. 1...
1.1 This specification covers requirements and test methods for annular corrugated profile wall polyethylene pipe and fittings with an interior liner. The inside diameters covered are 50?mm to 1500 mm [2?in. to 60 in.]. 1.2 The requirements of this specification are intended to provide non-pressure...