This test method furnishes a way of measuring, in the laboratory, the performance of a foaming chemical to be used in producing foam (air cells) for making cellular concrete. This test method includes the following: Manufacture of laboratory quantities of cellular...
1.1 This test method furnishes a way of measuring, in the laboratory, the performance of a foaming chemical to be used in producing foam (air cells) for making cellular concrete. 1.2 This test method includes the following: 1.2.1 Manufacture of laboratory quantities of cellular...
1.1 This specification covers the minimum requirements for the methods of application and finishing of gypsum board, including related items and accessories. 1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance...
This specification covers foaming agents specifically formulated for making preformed foam for use in the production of cellular concrete. The function of this specification is to provide the means for evaluating the performance of a specific foaming agent. This is...
1.1 This test method furnishes a way of measuring, in the laboratory, the performance of a foaming chemical to be used in producing foam (air cells) for making cellular concrete. 1.2 This test method includes the following: 1.2.1 Manufacture of laboratory quantities of cellular...
1.1 This specification covers the minimum requirements for the methods of application and finishing of gypsum board, including related items and accessories. 1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance...
3.1 This test method covers the determination of the air content of freshly mixed concrete. It measures the air contained in the mortar fraction of the concrete, but is not affected by air that may be present inside porous aggregate particles. 3.1.1 Therefore, this is the appropriate...
1.1 This specification covers the minimum requirements for the methods of application and finishing of gypsum board, including related items and accessories. 1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance...
Collection of Selected, peer reviewed papers from the 2013 3rd International Conference on Key Engineering Materials (ICKEM 2013), March 8-9, 2013, Kota Kinabalu, Malaysia. The 85 papers are grouped as follows: Chapter 1: Novel Composite Materials and their Characterization; Chapter 2: Advances in...
1.1 This specification covers the minimum requirements for the methods of application and finishing of gypsum board, including related items and accessories. 1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance...
4.1 Design professionals, for aesthetic reasons, have desired to limit the spacing and width of sealant joints on exterior walls and other locations of new buildings. Analysis of the performance factors and especially tolerances that affect a sealant joint is necessary to determine if a joint will...
4.1 Design professionals, for aesthetic reasons, have desired to limit the spacing and width of sealant joints on exterior walls and other locations of new buildings. Analysis of the performance factors and especially tolerances that affect a sealant joint is necessary to determine if a joint will...
3.1 This test method covers the determination of the air content of freshly mixed concrete. It measures the air contained in the mortar fraction of the concrete, but is not affected by air that may be present inside porous aggregate particles. 3.1.1 Therefore, this is the appropriate...
This practice applies to techniques that use nondestructive electrical impedance (EI) scanners to locate moisture and evaluate the comparitive moisture content within insulated low-slope roofing and waterproofing systems. This practice is applicable to roofing and waterproofing systems wherein...
1.1 This practice applies to techniques that use non-destructive electrical impedance (EI) scanners to locate moisture and evaluate the comparitive moisture content within insulated low-slope roofing and waterproofing systems. 1.2 This practice is applicable to roofing and waterproofing systems...
1.1 This practice applies to techniques that use non-destructive electrical impedance (EI) scanners to locate moisture and evaluate the comparitive moisture content within insulated low-slope roofing and waterproofing systems. 1.2 This practice is applicable to roofing and waterproofing systems...
The 235 peer-reviewed papers, making up the proceedings of the 2nd International Symposium on Chemical Engineering and Material Properties (ISCEMP 2012) held on the 22nd to 24th June in Taiyuan, Shanxi, China, are grouped into five chapters: Chemical Engineering; Materials Science and Engineering;...
3.1 This test method covers the determination of the air content of freshly mixed concrete. It measures the air contained in the mortar fraction of the concrete, but is not affected by air that may be present inside porous aggregate particles. 3.1.1 Therefore, this is the appropriate...
1.1 This practice applies to techniques that use non-destructive electrical impedance (EI) scanners to locate moisture and evaluate the comparitive moisture content within insulated low-slope roofing and waterproofing systems. 1.2 This practice is applicable to roofing and waterproofing systems...