loading
ASTM C1848-17a(2023) - Standard Practice for Installation of High-Pressure Spray Polyurethane Foam Insulation for the Building Enclosure
March 1, 2023 - ASTM International

1.1 This practice covers the installation of high-pressure spray polyurethane foam (SPF) as an insulation for building enclosure assemblies including: walls, ceilings, attics, floors, and crawl spaces. This practice does not apply to SPF used strictly as a component for an air barrier...

ASTM C1303/C1303M-22 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
June 1, 2022 - ASTM International

5.1 Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

ASTM D8142-23 - Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers
September 1, 2023 - ASTM International

6.1 SPF insulation is applied and formed onsite, which creates unique challenges for measuring product emissions. This test method provides a way to measure post-application chemical emissions from SPF insulation. 6.2 This test method can be used to identify compounds that emit from...

ASTM C1303/C1303M - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
March 1, 2019 - ASTM

This test method covers a procedure for predicting the long-term thermal resistance (LTTR) of unfaced or permeably faced rigid gas-filled closed-cell foam insulations by reducing the specimen thickness to accelerate aging under controlled laboratory conditions (1-5).2 NOTE 1-See...

ASTM C1303/C1303M-19 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
March 1, 2019 - ASTM International

5.1 Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

NEMA LE 7 - Recessed Luminaires Intended for Contact with Expanding Polyurethane Foam Insulation
January 1, 2015 - NEMA

This standard provides requirements and recommendations for Type IC recessed luminaires intended for installation in contact with low density and medium density polyurethane foam thermal insulation

GMKOREA EDS-M-6718 - Sticky Type Urethane Foam Insulation
June 1, 2011 - GMKOREA

Sound absorption/insulation materials used for noise reduction of automobiles. PURPOSE This standard specifies the physical properties and controlling quality of the sound absorption/insulation materials used for automobiles.

ASTM C1534-22 - Standard Specification for Flexible Polymeric Foam Sheet Insulation Used as a Thermal and Sound Absorbing Liner for Duct Systems
November 1, 2022 - ASTM International

This specification covers the composition, dimensions, and physical properties of flexible unfaced foam sheet, used to insulate interior surfaces of HVAC ducts, plenums and equipment used for the distribution of conditioned air. The flexible polymeric insulations of this specification...

ASTM D8445-22a - Standard Practice for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation Samples in a Large-scale Ventilated Enclosure
September 1, 2022 - ASTM International

1.1 This practice describes procedures for measuring the chemical emissions of volatile and semi-volatile organic compounds (VOCs and SVOCs) from spray polyurethane foam (SPF) insulation samples in a large-scale ventilated enclosure. 1.2 This practice is used to identify emission...

ASTM C1848-17a - Standard Practice for Installation of High-Pressure Spray Polyurethane Foam Insulation for the Building Enclosure
September 1, 2017 - ASTM International

1.1 This practice covers the installation of high-pressure spray polyurethane foam (SPF) as an insulation for building enclosure assemblies including: walls, ceilings, attics, floors, and crawl spaces. This practice does not apply to SPF used strictly as a component for an air barrier...

GMKOREA EDS-M-6657 - Polyurethane Foam for Insulation
June 1, 2011 - GMKOREA

For sound absorption and insulation used for the floor panel and inner dash panel of automobiles. PURPOSE This specification specifies the requirements of basic property of the polyurethane foam used for sound absorption and insulation of automobile..

ASTM D8445-22 - Standard Practice for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation Samples in a Large-scale Ventilated Enclosure
May 1, 2022 - ASTM International

1.1 This practice describes procedures for measuring the chemical emissions of volatile and semi-volatile organic compounds (VOCs and SVOCs) from spray polyurethane foam (SPF) insulation samples in a large-scale ventilated enclosure. 1.2 This practice is used to identify emission...

ASTM C1848-17 - Standard Practice for Installation of High-Pressure Spray Polyurethane Foam Insulation for the Building Enclosure
February 1, 2017 - ASTM International

1.1 This practice covers the installation of high-pressure spray polyurethane foam (SPF) as an insulation for building enclosure assemblies including: walls, ceilings, attics, floors, and crawl spaces. This practice does not apply to SPF used strictly as a component for an air barrier...

ASTM C1848 - Standard Practice for Installation of High-Pressure Spray Polyurethane Foam Insulation for the Building Enclosure
September 1, 2017 - ASTM

This practice covers the installation of high-pressure spray polyurethane foam (SPF) as an insulation for building enclosure assemblies including: walls, ceilings, attics, floors, and crawl spaces. This practice does not apply to SPF used strictly as a component for an air barrier...

ASTM C1303/C1303M-15 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
December 1, 2015 - ASTM International

5.1 Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

ISO 21844 - Cellular plastic - Cellulose foam thermal insulation - Material specification
April 1, 2018 - ISO

This document specifies material requirements and identifies the test methods to be used to determine these requirements for cellulose foam for thermal insulation for buildings and other applications. There are four categories of material characterized by the density of the material.

DS/EN 17333-5 - Characterisation of one component foam – Part 5: Insulation
March 23, 2020 - DS

This document specifies test methods for the evaluation of the insulation properties for moisture curing, self-curing activatable or water drying foams dispensed from single pressurised foam containers. This document does not purport to address all of the safety concerns, if...

GME TM 604700 - General Requirements on Polyurethane Foam for Insulations
August 1, 2018 - GME

The scope of this Standard is to specify the inter-Emergency Services Network interactions for initial emergency calls that are required to be routed to another Emergency Service Network and calls that may be transferred (bridged) between Emergency Services Networks. This Standard is incremental to...

ASTM C1303/C1303M-14 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
April 15, 2014 - ASTM International

5.1 Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

DEF STAN 02-803 - Requirements for Polymer Foam Products for Thermal Insulation
October 14, 2019 - MODUK

This Defence Standard (Def Stan) specifies technical requirements for two types of polymer foam products for use in thermal insulation applications on HM Ships and Submarines. Requirements that are common to all types of polymer foam products are described in the main part of...

Advertisement