1.1 These test methods cover the procedures for the classification of mineral fiber insulation as flexible, resilient flexible, semirigid, or rigid. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may...
1.1 This test method covers the determination of moisture in mineral aggregate for use on built-up roofs. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each...
This specification covers ground calcium carbonate (GCC, a type of ground limestone) and other finely divided aggregate mineral filler (AMF) materials for use in concrete mixtures. It defines the types of GCC and AMF materials for use in concrete. If concrete in service is subject to sulfate...
1.1 This test method covers the determination of hardness of all types of mineral surfacing for use on built-up roofs and is intended to provide an index of their ability to withstand physical breakdown in handling. 1.2 The values stated in either SI units or inch-pound units are to be...
1.1 This specification establishes requirements for compacted, mineral-insulated, metal-sheathed (MIMS), base metal thermocouple cable,2 with at least two thermoelements.3 1.2 This specification describes the required material, processing and testing requirements, optional supplementary...
1.1 These test methods cover the determination of the following properties of refractory shapes: 1.1.1 Apparent porosity, 1.1.2 Liquid absorption, 1.1.3 Apparent specific gravity, and 1.1.4 Bulk density. 1.2 These test methods are applicable to all refractory shapes except those that chemically...
1.1 These test methods are intended for use in determining the total, neutral, and combined acid sulfate in mineral-tanned leather. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not...
1.1 This test method covers a procedure for determining the non-fibrous content (shot) of man-made rock and slag mineral fiber insulation. The procedure covers a dry sieve analysis method to distinguish between fiberized and non-fiberized (shot) portions of a specimen of man-made rock and...
5.1 Some petroleum products are treated with mineral acid as part of the refining procedure. Obviously, any residual mineral acid in a petroleum product is undesirable. The absence of a positive indication in the test for acidity of the distillation residue or aqueous extract of a...
1.1 This practice covers the application of mineral-colloid-stabilized,
1.1 This test method2 is an analytical procedure using transmission electron microscopy (TEM) for the determination of the concentration of asbestos structures in ambient atmospheres and includes measurement of the dimension of structures and of the asbestos fibers found in the structures from...
1.1 This specification covers the composition and physical properties of mineral-fiber blanket insulation used to thermally or acoustically insulate ceilings, floors, and walls in light frame construction and manufactured housing. The requirements cover fibrous blankets and facings. Values...
1.1 This test method covers a procedure for comparing the behavior of refractories in contact with vapors under conditions intended to simulate the environment within a glass-melting or other type of furnace when refractories are exposed to vapors from raw batch, molten glass, fuel, fuel...
4.1 The extent of cracking or pitting of bituminous films is a measure of the extent of deterioration due to weathering. Failure due to cracking is more accurately determined electrically than visually. 4.2 Failure determined by this test method will depend not only on the characteristics of the...
1.1 This specification covers the requirements for simplex, compacted mineral-insulated, metal-sheathed (MIMS), Type K and N thermocouples for nuclear or other high reliability service. Depending on size, these thermocouples are normally suitable for operating temperatures to 1652?°F...
This specification deals with the standards for asphalt roofing in shingle form, composed of glass felt or felts impregnated and coated on both sides with asphalt, and surface on the weather side with minerals. Physical requirements of the shingles such as behavior on melting, tear strength,...
1.1 This test method covers evaluation of strength in tension on mineral fiber batt- and blanket-type insulation products. It is useful for determining the comparative tensile properties of these products, specimens of which cannot be held by the more conventional clamp-type grips. This is a...
This specification covers coal tar adhesive with or without polymer modification suitable for brush, spray, squeegee and trowel application to coal tar built up and coal tar modified bitumen membrane roofings and flashings. The adhesive shall be classified as: Type I and Type II. Coal tar adhesive...
1.1 This practice covers the types of and preparation of containers found most suitable for the handling of hydrocarbon samples for the determination of total mercury. 1.2 This practice was developed for sampling streams where the mercury speciation is predominantly Hg(0) present as a mixture of...