1.1 This test method covers an engine test procedure for the measurement of the effects of automotive engine oils on the fuel economy of passenger cars and light-duty trucks with gross vehicle weight 3856 kg or less. The tests are conducted using a specified spark-ignition engine with a...
5.1 Thermocouples fabricated from thermocouple cable that has been contaminated by moisture or by other impurities may undergo large changes in thermoelectric properties or may fail catastrophically when exposed to high temperatures. Since such contamination usually lowers the...
1.1 This engine lubricant test method is commonly referred to as the Roller Follower Wear Test. Its primary result, roller follower shaft wear in the hydraulic valve lifter assembly, has been correlated with vehicles used in stop-and-go delivery service prior to 1993. It is one of the test methods...
6.1 This guide presents techniques on the use of thermocouples and associated equipment for measuring temperature in elevated-temperature
This specification covers the performance requirements for general-purpose air incubators ordinarily used for incubating procedures. It is applicable to gravity and forced ventilation incubators designed to operate over a specified range of temperature. This specification does not include any...
This specification covers concentric lay stranded and rope-lay stranded round electrical conductor fabricated from copper, copper alloy or aluminum. This specification also covers thermocouple extension conductor fabricated from nickel/chromium or nickel/aluminum/mang
This specification covers the requirements for magnesium oxide (MgO) and aluminum oxide (Al2O3) powders and crushable insulators used to manufacture metal-sheathed platinum resistance thermometers (PRTs), noble metal thermocouples, base metal thermocouples, and their respective cables...
1.1 This practice contains reporting requirements for thermometer calibrations included in ASTM Committee E20 Test Methods. 1.2 This practice covers reports of calibration for radiation thermometers, liquid-in-glass thermometers, resistance thermometers, digital thermometers, and new...
5.1 Many electronic instruments that are designed to be used with thermocouples use some method of reference junction compensation. In many industrial applications it may be impractical to use a physical ice bath as a temperature reference in a thermocouple circuit. The instrument...
QUALIFIED PRODUCT LIST OF PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION MIL-I-9343 Indicator, Temperature, Thermocouple, Engine Exhaust, Type MJ-1 This QPL has been prepared for use by or for the Government in the acquisition of products covered by the subject specification and...
QUALIFIED PRODUCT LIST OF PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION MIL-I-27552 Indicator, Temperature, Thermocouple EHU-15A/A, Potentiometer Type, White Lighted This QPL has been prepared for use by or for the Government in the acquisition of products covered by the subject...
5.1 This test method is designed to calibrate a thermoelement at one or more test temperatures. The data obtained are sometimes referred to as initial values of emf because the time at the test temperature is limited. 5.2 This test method is employed mainly by providers of spools or coils of wire...
IEC 60584-3:2021 It is necessary for thermocouple temperature measurement that the electro-motive force (abbreviated as e.m.f. hereafter) of the thermocouple circuit is precisely measured by a measuring instrument. A thermocouple is electrically connected to the instrument by a...
This SAE Aerospace Standard (AS) covers the requirements for thermocouple extension cable. Manufacturers of primary thermocouple wire in accordance with this specification must be qualified to the similar wire type specified in Table 1 .
QUALIFIED PRODUCT LIST OF PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION MIL-T-24388 Thermocouple and Resistance Temperature Detector Assemblies, General Specification for (Naval Shipboard) This list has been prepared for use by or for the Government in the acquisition of products...
This guide consists of reference tables that give temperature-electrom
This guide describes tests that may be applied to new or previously used thermocouples for the purpose of verification. Some of the tests perform a suitable verification by themselves, but many tests merely alert the user to serious problems if the thermocouple fails the test. Some of...
5.1 These verification tests may be performed by users or calibrators of thermocouples. The methods are useful for both new and used thermocouples. They provide a means to assess the accuracy with which a thermocouple is capable of measuring temperature. 5.2 Results from these...
5.1 The application of HFTs and temperature sensors to building envelopes provide in-situ data for evaluating the thermal performance of an opaque building component under actual environmental conditions, as described in Practices C1046 and C1155. These applications require calibration of the HFTs...
The object of this document is to determine the composition, nature of materials, manufacturing tests and thermoelectronic behaviour of connectors for sensors using thermocouples according to EN 60584-3:2008. This document does not cover such special thermocouples as U, L and W types;...