This set contains: TIA-322 The scope of this Standard is limited to providingengineering
1.1 This specification covers re-refined engine oil bottoms, also known as vacuum tower asphalt extender, that may be used in formulating asphalt for pavement construction and roofing. This specification has been developed specifically for these two categories of product and is not intended...
1.1 These practices cover procedures for measuring one-, two-, or three-dimensional vector wind components and sonic temperature by means of commercially available sonic anemometer/thermomet
1.1 This test method describes a simple procedure for the quantification of culturable, waterborne bacteria in potable water (drinking water, bottled water, and dental water, for example) and non-potable waters (cooling towers, for example). 1.1.1 The EasyDisc2, 3 plate format is designed to...
4.1 Chloride ion is under regulation in waste water, and must, therefore, be measured accurately. It is highly detrimental to high-pressure boiler systems and to stainless steel, so monitoring is essential for prevention of damage. Chloride analysis is widely used as a tool for estimating the...
1.1 This practice covers the determination of the thickness of glass installed in airport traffic control towers (ATCT) to resist a specified design loading with a selected probability of breakage less than or equal to either 1 lite per 1000 or 4 lites per 1000 at the first occurrence of the...
1.1 This test method covers the procedures for determining the capability of climbing and ladder treestands, climbing sticks (Sectional and Continuous), and tripods/towers to withstand repeated loading relative to the manufacturer's rated capacity. For actual specification requirements for...
1.1 This specification covers cold-formed welded carbon steel hollow structural sections (HSS) for welded or bolted construction. These shapes are utilized in but not limited to the following applications: buildings, bridges, towers, cranes, sign supports and poles, off-shore production and...
1.1 This practice provides guidelines for acoustic emission (AE) examinations of fiberglass reinforced plastic (FRP) fan blades of the type used in industrial cooling towers and heat exchangers. 1.2 This practice uses simulated service loading to determine structural integrity. 1.3 This...
The ASME B30 Standard contains provisions that apply to the construction, installation, operation, inspection, testing, maintenance, and use of cranes and other lifting and material-movement-re
1.1 This test method covers procedures for static loading of various components of treestands, climbing sticks, and tripod/tower stands that are used for hunting, photographing, or general observation. This test method does not specify actual rated load capacities and corresponding factors...
5.1 Sodars have found wide applications for the remote measurement of wind and turbulence profiles in the atmosphere, particularly in the gap between meteorological towers and the lower range gates of wind profiling radars. The sodar's far field acoustic power is also used for refractive...
1.1 This practice provides procedures to measure representative near-surface atmospheric (outdoor air) temperature for meteorological purposes using commonly available electrical thermometers housed in radiation shields mounted on stationary or portable masts or towers. 1.2 This practice is...
This document specifies the requirements of anti-collision devices and systems installed on tower cranes (as defined in EN 14439) to avoid the risks of collision between several cranes in service, between a crane in use and fixed obstacles, and over prohibited zones. It also specifies the...
1.1 This test method describes a simple procedure for the detection of Legionella pneumophila (L. pneumophila) in potable water and non-potable waters (cooling towers, for example). This procedure describes a liquid culture method based on a bacterial enzyme technology. The detection of L....
1.1 This test method covers the determination of residual chlorine in water by direct amperometric titration. 1.2 Within the constraints specified in Section 6, this test method is not subject to commonly encountered interferences and is applicable to most waters. Some waters, however, can exert an...
5.1 This practice is provided to develop and maintain uniformity in practices for instructions for treestands, climbing sticks (continuous and sectional), tripods, and towers, particularly with regard to quality assurance and safety. 5.2 It is emphasized that the use of these practices will...
1.1 These test methods cover procedures to be followed in testing the performance of permanent metal railing systems (guard, stair, and ramp-rail systems), including components such as rails (hand, wall, grab, and transfer rails) and swing gates or other forms of required guardrail opening...
This document establishes required practices for the safe use of tower cranes. Subjects covered include safe systems of work, management, planning, selection, erection and dismantling, special base, operation and maintenance of cranes and the selection of operators, slingers and signalers....