5.1 The plastic Petri plate (carrier) provides a closed system for enumeration and easy application of a pre-saturated or impregnated antimicrobial towelette by an analyst. 5.2 Aliquoting of sterile 5?% non-heat-inactivated
This test method deals with the standard procedures for establishing the relative bond strength of Grade 270 prestressing steel strands of specified diameter in cement grout as used in prestressed ground anchors for evaluating the effects of manufacturing practices on bond strength. The bond...
This specification covers a cleaner in the form of a liquid.
1.1 This practice may be used to extract nonvolatile and semivolatile residues from materials such as new and used gloves, new and used wipes, component soft goods, and so forth. When used with proposed cleaning materials (wipes, gloves, and so forth), this practice may be used to...
1.1 This practice is intended to be used to reduce the cytotoxic level of the virus-test product mixture prior to assaying for viral infectivity. It is used in conjunction with evaluations of the virucidal efficacy of disinfectant solutions, wipes, trigger sprays, or pressurized disinfectant...
1.1 The purpose of this guide is to establish a procedure to select cleaning agents, both solvents and water-based detergents, for oxygen-enriched systems. This includes laboratory-scale tests for cleaning effectiveness, materials compatibility, and oxygen compatibility. 1.2 The effectiveness of a...
1.1 This guide covers how to conduct, document, and report findings of a lead hazard assessment of dwellings and of other child-occupied facilities. 1.2 Procedures for assessment of personal items, such as toys, dishes, and hobby materials that may contribute to elevated lead levels in blood are...
This specification covers the requirements relating to rinsed and non rinsed chromate conversion coatings on aluminum and aluminum alloys intended to give protection against corrosion and as a base for other coatings. Aluminum and aluminum alloys are chromate coated in order to retard corrosion; as...
This test method covers the determination of the resistance of porcelain-enameled utensils to thermal shock. A hot plate, timing device, container, and sponge shall be used. The surface temperature of the hot plate, determined by any suitable surface temperature measuring device, may be varied by...
1.1 This test method covers quantitatively determining biocarbon content of liquid hydrocarbon fuels with a focus on those produced in a typical petroleum refinery using liquid scintillation counting (LSC). The method is designed to generate analogous results as Test Method D6866 Method C, for low...
1.1 This test method is intended for use in the determination of beryllium by sampling workplace air and surface dust. 1.2 This test method assumes that air and surface samples are collected using appropriate and applicable ASTM International standard practices for sampling of workplace air and...
4.1 Plastic materials, when used as transparencies, covers, or enclosures, are subject to wiping, cleaning, or other types of rubbing actions that cause abrasion. It is the intent of this test method to provide a means of estimating the resistance of such materials to this type and degree of...
5.1 Knowledge of the critical surface tension of substrates, primers and other coatings is useful for explaining or predicting wettability by paints and other coatings applied to those surfaces. Surfaces with low critical surface tensions usually are prone to suffer defects such as crawling,...
1.1 This practice covers various types of cold rolled steel panels and the procedures to be followed in their preparation for testing paint, varnish, lacquer, conversion coatings, and related products. 1.2 The procedures are as follows: Procedure A-Conversion coatings (phosphates, chromates, ?etc.)...
This SAE Recommended Practice establishes a uniform procedure for assuring the manufactured quality, installed utility and performance of automotive products to the relocation, alteration, replacement, and/or extension of secondary controls and systems other than those provided by the vehicle...
1.1 This specification covers requirements for premoistened wipe materials that are used to collect settled dusts on surfaces for the subsequent determination of beryllium. 1.2 For wipe materials used for the determination of lead in surface dust, refer to Specification E1792. This is...
5.1 This practice is for use in the preparation of no more than four wipe samples combined to form a composited sample for subsequent determination of lead content. 5.2 This practice assumes use of wipes that meet Specification E1792 and should not be used unless the wipes meet...
5.1 This practice is for use in the preparation of no more than four wipe samples collected from equally-sized areas in the same space combined to form a composited sample for subsequent determination of lead content. 5.2 This practice assumes use of wipes that meet Specification...
5.1 This practice is intended for the digestion of lead in dust wipe samples collected during various lead hazard activities performed in and around buildings and related structures. 5.2 This practice is also intended for the digestion of lead in dust wipe samples collected during and...
1.1 This test method covers the determination of lead (Pb) in dust by wipe, paint, and soil collected in and around buildings and related structures by flame atomic absorption spectrophotometry (FAAS) and is derived from Test Methods D4185 and E1613. For determination of lead (Pb) and other...