1.1 This test method covers the steps necessary for the preparation and analysis by X-rayfluorescence (XRF) of mineral acid solutions containing uranium. 1.2 This test method is valid for those solutions containing 0.05 to 20 g uranium/L as presented to the spectrometer...
This test method is applicable to aqueous solutions of uranium containing 0.05 to 20 g uranium per litre of solution presented to the spectrometer. Either wavelength-dispersive or energy-dispersive X-rayfluorescence systems may be used provided the software accompanying...
5.1 X-rayfluorescence spectrometry can provide an accurate determination of metallic and many non-metallic elements in a wide variety of solid and liquid materials. This guide covers the information that should be included in an X-ray spectrometric analytical...
This Standard specifies an X-rayfluorescence solution method for the determination of cobalt, iron, manganese, molybdenum, nickel, niobium, tantalum, titanium, tungsten, vanadium and zirconium contents of carbides and hardmetals.
This Standard specifies an X-rayfluorescence solution method for the determination of cobalt, iron, manganese, molybdenum, nickel, niobium, tantalum, titanium, tungsten, vanadium and zirconium contents of carbides and hardmetals.
This International Standard specifies an X-rayfluorescence fusion method for the determination of cobalt, chromium, iron, manganese, molybdenum, nickel, niobium, tantalum, titanium, tungsten, vanadium and zirconium contents of carbides and hardmetals.
This International Standard specifies an X-rayfluorescence fusion method for the determination of cobalt, chromium, iron, manganese, molybdenum, nickel, niobium, tantalum, titanium, tungsten, vanadium and zirconium contents of carbides and hardmetals.
This guide describes the components for a wavelength-dispersive X-rayfluorescence system for materials analysis. This guide can be used as a reference in the apparatus section of test methods for wavelength-dispersive X-rayfluorescence (WDXRF2) analyses...
1.1 This guide describes the components for a wavelength-dispersive X-rayfluorescence system for materials analysis. This guide can be used as a reference in the apparatus section of test methods for wavelength-dispersive X-rayfluorescence (WDXRF)...
5.1 X-rayfluorescence spectrometry can provide an accurate determination of metallic and many non-metallic elements in a wide variety of solid and liquid materials. This guide covers the information that should be included in an X-ray spectrometric analytical...
This guide describes the components for an energy-dispersive X-rayfluorescence (XRF) system for materials analysis. It can be used as a reference in the apparatus section of test methods for energy-dispersive X-rayfluorescence analyses of nuclear...
1.1 This guide describes the components for an energy-dispersive X-rayfluorescence (XRF) system for materials analysis. It can be used as a reference in the apparatus section of test methods for energy-dispersive X-rayfluorescence analyses of nuclear...
1.1 This guide describes the components for an energy-dispersive X-rayfluorescence (XRF) system for materials analysis. It can be used as a reference in the apparatus section of test methods for energy-dispersive X-rayfluorescence analyses of nuclear...
1.1 This practice describes the components of a wavelength-dispersive X-rayspectrometer that are basic to its operation and to the quality of its performance. It is not the intent of this practice to specify component tolerances or performance criteria, as these are unique for...
1.1 This practice describes the components of a wavelength-dispersive X-rayspectrometer that are basic to its operation and to the quality of its performance. It is not the intent of this practice to specify component tolerances or performance criteria, as these are unique for...
1.1 These test methods cover the determination of ten major elements (SiO2, Al2O3, Fe2O3, MgO, CaO, Na2O, K2O, TiO2, P2O5, MnO, and LOI in ceramic whitewares clays and minerals using wavelength dispersive X-rayfluorescence spectrometry (WDXRF). The sample is first ignited,...
1.1 This test method covers the analysis of stainless and alloy steels by wavelength dispersive X-rayFluorescence Spectrometry for the determination of the following elements: Note 1 Unless exceptions are noted, concentration ranges can be extended by the use of suitable...
1.1 This test method covers the X-rayfluorescence analysis of 6Al-4V titanium alloy for the following elements in the ranges indicated: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user...
This European Standard specifies the procedure for a quantitative determination of major and trace element concentrations in homogeneous solid waste, soil and soil-like material by energy dispersive X-rayfluorescence (EDXRF) spectrometry or wavelength dispersive...
This document specifies the procedure for a determination of major and minor element concentrations in solid recovered fuel material by energy dispersive X-rayfluorescence (EDXRF) spectrometry or wavelength dispersive X-rayfluorescence (WDXRF)...