CEI EN 60601-2-23

Medical electrical equipment Part 2: Particular requirements for basic safety and essential performance of transcutaneous partial pressure monitoring equipment

active, Most Current
Buy Now
Organization: CEI
Publication Date: 1 April 2016
Status: active
Page Count: 54
ICS Code (Diagnostic equipment): 11.040.55
scope:

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of TRANSCUTANEOUS PARTIAL PRESSURE MONITORING EQUIPMENT as defined in 201.3.63 and hereinafter referred to as ME EQUIPMENT, whether this ME EQUIPMENT is stand alone or part of a system.

This standard applies to transcutaneous monitors used with adults, children and neonates, and it includes the use of these devices in foetal monitoring during birth.

This standard does not apply to haemoglobin saturation oximeters or to devices applied to surfaces of the body other than the skin (for example conjunctiva, mucosa).

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the General Standard

Document History

CEI EN 60601-2-23
April 1, 2016
Medical electrical equipment Part 2: Particular requirements for basic safety and essential performance of transcutaneous partial pressure monitoring equipment
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of TRANSCUTANEOUS PARTIAL PRESSURE MONITORING EQUIPMENT as defined in 201.3.63 and hereinafter referred to as ME...
May 1, 2001
Medical electrical equipment - Part 2-23: Particular requirements for the safety, including essential performance, of transcutaneous partial pressure monitoring equipment
La Norma specifica le prescrizioni particolari di sicurezza, comprese le prestazioni essenziali, degli apparecchi per il monitoraggio della pressione parziale per via transcutanea, compresi i...
February 1, 1999
Apparecchi elettromedicali - Parte 2: Norme particolari per la sicurezza di apparecchi di monitoraggio di pressione parziale per via transcutanea
La Norma si applica agli apparecchi di monitoraggio intesi come dispositivo e trasduttori associati per monitorare e/o registrare la pressione parziale di gas in corrispondenza della superficie...