ASTM International - ASTM E803-17

Standard Test Method for Determining the L/D  Ratio of Neutron Radiography Beams

active
Buy Now
Organization: ASTM International
Publication Date: 1 November 2017
Status: active
Page Count: 7
ICS Code (Non-destructive testing): 19.100
significance And Use:

4.1 The quality of a neutron radiographic image is dependent upon many factors. The L/D ratio is one of those factors and constitutes a numerical definition of the geometry of the neutron... View More

scope:

1.1 This test method defines an empirical technique for the measurement of the effective collimation ratio, L/D, of neutron radiography beams. The technique is based upon analysis of a neutron radiographic image and is independent of measurements and calculations based on physical dimensions of the collimation system. The values derived by this technique should be more accurate than those based on physical measurements, particularly for poorly defined apertures.

1.2 This test method covers both the manufacture and use of the device to measure L/D ratios.

1.3 Neutron images for this method can be produced on radiographic film using an appropriate conversion screen as detailed in Guide E748 or a CR screen with appropriate neutron converter. The method has not been validated with images produced by digital detector arrays.

1.4 This test method only applies to neutron beam lines with cold or thermal neutron spectrums.

1.5 The values stated in SI units are to be regarded as standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM E803-17
November 1, 2017
Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams
1.1 This test method defines an empirical technique for the measurement of the effective collimation ratio, L/D, of neutron radiography beams. The technique is based upon analysis of a neutron...
June 1, 2013
Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams
4.1 The quality of a neutron radiographic image is dependent upon many factors. The L/D ratio is one of those factors and constitutes a numerical definition of the geometry of the neutron beam. The...
July 1, 2008
Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams
The quality of a neutron radiographic image is dependent upon many factors. The L/D ratio is one of those factors and constitutes a numerical definition of the geometry of the neutron beam. The L/D...
January 1, 1996
Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams
1.1 This method defines an empirical technique for the measurement of the effective collimation ratio, L/D , of neutron radiography beams. The technique is based upon analysis of a neutron...
May 15, 1991
Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams
The quality of a neutron radiographic image is dependent upon many factors. The L/D ratio is one of those factors and constitutes a numerical definition of the geometry of the neutron beam. The L/D...
January 1, 1991
Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams
A description is not available for this item.