UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

CEI - EN IEC 60601-2-21

Medical electrical equipment Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers

active, Most Current
Organization: CEI
Publication Date: 1 April 2022
Status: active
Page Count: 46
ICS Code (Anaesthetic, respiratory and reanimation equipment): 11.040.10
scope:

This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT.

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the general standard.

This particular standard specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.

This particular standard does not apply to:

• devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35;

• INFANT INCUBATORS; for information, see IEC 60601-2-19;

• INFANT TRANSPORT INCUBATORS, for information, see IEC 60601-2-20;

• INFANT PHOTOTHERAPY EQUIPMENT, for information, see IEC 60601-2-50.

SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED RADIANT WARMER including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56.

Document History

EN IEC 60601-2-21
April 1, 2022
Medical electrical equipment Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is...
September 1, 2017
Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of infant radiant warmers
FOREWORD This amendment has been prepared by subcommittee 62D: Electromedical equipment of IEC technical committee 62: Electrical equipment in medical practice Full information on the voting for...
March 1, 2012
Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of infant radiant warmers
A description is not available for this item.
May 1, 2011
Medical electrical equipment Part 2: Particular requirements for basic safety and essential performance of infant radiant warmers
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is...

References

Advertisement