SNV - SN EN 15544
One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) - Dimensioning
| Organization: | SNV |
| Publication Date: | 1 February 2023 |
| Status: | active |
| Page Count: | 26 |
| ICS Code (Solid fuel heaters): | 97.100.30 |
scope:
The application of the calculations of this document enables a verification of the emission values carbon monoxide, nitrogen dioxide, organically bound carbon as well as dust and the energy efficiency.
Complying with the calculations of this document results in emission values less or equal for carbon monoxide 1 500 mg/mn3 (1 000 mg/MJ), nitrogen dioxide 225 mg/mn3 (150 mg/MJ), organically bound carbon 120 mg/mn3 (80 mg/MJ) and dust 90 mg/mn3 (60 mg/MJ). If the calculations of this document are used in combination with suitable combustion chambers that prove lower emission values in a type test, these values are also considered to be complied with.
There might be national or local regulations, which impose stricter legal emissions and/or efficiency requirements.
This document specifies calculations for the dimensioning of Kachelgrundöfen/Putz
This document is applicable for Kachelgrundöfen/Putz
This document is applicable for Kachelgrundöfen/Putz
This document also applies to the combination with combustion chambers that are suitable for one-off Kachelgrundöfen/Putz
The following general conditions apply to such combustion chambers:
- with an air-fuel ratio of between 1,95 and 3,95 according to the type test;
- with a maximum load from 5 kg to 40 kg;
- using other suitable materials as well as fireclay.
With regard to the type test, this document is applicable for combustion chambers which are tested:
- according to EN 15250 (or EN 16510-2-51);
- according to EN 13229 (or EN 16510-2-2); or
- according to respective national standards (e.g. ÖNORM B 8303).
This document is applicable for type tested combustion chambers designed for batch fired pellet burning if meeting the requirements according to this document (air-fuel ratio between 1,95 and 3,95, the load of the pellets burned in (78 ± 20) min).
This document is not applicable for:
- combinations with water heat exchangers for central heating or other heat absorbing elements like open water tanks, etc.;
- combustion chambers with glass plates greater than 1/5 of the combustion chamber surface;
- mass-produced prefabricated stoves (slow heat release appliances) or partly prefabricated stoves (slow heat release appliances) according to EN 15250 (or EN 16510-2-51).
1 Under preparation. Stage at the time of publication: prEN 16510-2-5:2023.