D5617

Standard Test Method for Multi-Axial Elongation of Geomembranes

active, Most Current
Publication Date: 1 November 2023
Status: active
Page Count: 5
ICS Code (Geotextiles): 59.080.70
scope:

This test method covers the measurement of the out-of-plane response of a geomembrane to a force that is applied perpendicular to the initial plane of the sample.

When the geomembrane deforms to a prescribed geometric shape (arc of a sphere or ellipsoid), formulations are provided to convert the test data to biaxial tensile stress-strain values. These formulations cannot be used for other geometric shapes. With other geometric shapes, comparative data on deformation versus pressure is obtained.

This test method requires a large-diameter pressure vessel (610 mm). Information obtained from this test method may be more appropriate for design purposes than many smallscale index tests.

The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

D5617
November 1, 2023
Standard Test Method for Multi-Axial Elongation of Geomembranes
This test method covers the measurement of the out-of-plane response of a geomembrane to a force that is applied perpendicular to the initial plane of the sample. When the geomembrane deforms to a...
June 1, 2004
Standard Test Method for Multi-Axial Tension Test for Geosynthetics
This test method covers the measurement of the out-ofplane response of geosynthetics to a force that is applied perpendicular to the initial plane of the sample.  When the geosynthetic deforms to a...
June 1, 2004
Standard Test Method for Multi-Axial Tension Test for Geosynthetics
This test method covers the measurement of the out-ofplane response of geosynthetics to a force that is applied perpendicular to the initial plane of the sample. When the geosynthetic deforms to a...
June 1, 2004
Standard Test Method for Multi-Axial Tension Test for Geosynthetics
This test method covers the measurement of the out-of-plane response of geosynthetics to a force that is applied perpendicular to the initial plane of the sample. When the geosynthetic deforms to a...
January 10, 1999
Standard Test Method for Multi-Axial Tension Test for Geosynthetics
1. Scope 1.1 This test method covers the measurement of the out-of-plane response of geosynthetics to a force that is applied perpendicular to the initial plane of the sample. 1.2 When the...
January 10, 1999
Standard Test Method for Multi-Axial Tension Test for Geosynthetics
1. Scope 1.1 This test method covers the measurement of the out-of-plane response of geosynthetics to a force that is applied perpendicular to the initial plane of the sample. 1.2 When the...
January 10, 1999
Standard Test Method for Multi-Axial Tension Test for Geosynthetics
This test method covers the measurement of the out-of-plane response of geosynthetics to a force that is applied perpendicular to the initial plane of the sample. When the geosynthetic deforms to a...
January 1, 1994
Standard Test Method for Multi-Axial Tension Test for Geosynthetics
A description is not available for this item.

References

Advertisement