UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

NR/L3/SIG/11761/D320

EBI Track 200 Modifications to Tuning Unit and ETU T1/T2 Connections and Trackside Wiring Recommendations - Application Note

active, Most Current
Buy Now
Organization: NR
Publication Date: 13 January 2012
Status: active
Page Count: 9
scope:

INTRODUCTION1

TI21 Tuning Units and ETUs are known to be prone to connection problems at the T1/T2 terminals where the track tails are terminated onto the unit. Investigation has shown that the termination arrangements for the 10mm tail cable crimp can become slack owing to the 'Back nut' becoming loose. The resulting loose connection causes degradation in performance, often leading to right side failure.

For new build Tuning Units and ETUs, Bombardier have altered the terminal arrangement to remove the 'Back nut' and these units are identified by mod strike as follows:

New build TU with modification = mod strike 3

New build ETU with modification = mod strike 4

This application note contains:

• Instructions detailing how to modify the terminal arrangement of earlier TUs and ETUs to eliminate the slack back nut problem.

• Recommendations for Tuning Unit trackside wiring which will optimise pole/zero performance.

1 The illustrations in this application note are clearest when viewed in colour.

Document History

NR/L3/SIG/11761/D320
January 13, 2012
EBI Track 200 Modifications to Tuning Unit and ETU T1/T2 Connections and Trackside Wiring Recommendations - Application Note
INTRODUCTION1 TI21 Tuning Units and ETUs are known to be prone to connection problems at the T1/T2 terminals where the track tails are terminated onto the unit. Investigation has shown that the...
September 20, 2010
Application/Guidance Note - Modifications to EBI Track 200 TI21 Tuning Unit & ETU T1 & T2 Connections & Trackside Wiring Recommendations
INTRODUCTION1 TI21 Tuning Units and ETUs are known to be prone to connection problems at the T1/T2 terminals where the track tails are terminated onto the unit. Investigation has shown that the...
Advertisement