scope:
This specification covers two types of trailer mounted liquefied petroleum gas (lpg) and kerosene fueled, bitumen heating kettles. The kettles shall be used for heating, transporting, and pressure discharging bitumen materials used in paving and roofing applications.
The kettles shall be of the following types, styles, and sizes as specified (see 6.2).
Type I Bottom fired (road kettle).
Type II Tube fired (roofing kettle).
Style A Lpg as burner and engine fuel.
Style B Kerosene (light oil) as burner fuel and gasoline as engine fuel.
Style C Lpg as burner fuel and gasoline as engine fuel.
Size 80 Melting tank capacity of 80 gallons (303 litre (L)).
Size 165 Melting tank capacity of 165 gallons (625 L).
Size 250 Melting tank capacity of 250 gallons (946 L).
Size 350 Melting tank capacity of 3 ) 50 gallons (1 3 25 L). Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data which may improve this document should be sent to: Commanding Officer (Code 1581), Naval Construction Battalion Center, 1000 23rd Avenue, Port Hueneme, CA 93043-4301, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.
intended Use:
Type I kettles are intended for use in melting and dispensing all types of bituminous material for maintenance of roadways, runways, and parking aprons. Type II kettles are intended for use in... View More