IEEE 433

Proposed Test Procedure for MAGNETIC AMPLIFIERS

inactive
Buy Now
Organization: IEEE
Publication Date: 1 January 1959
Status: inactive
Page Count: 7
scope:

FOREWORD

The magnetic amplifier definitions contained in A I E E Transactions Paper No. 58-175 are adhered to. In addition, the following definitions are presented for clarity only; they are not a part of the proposed test procedure, nor have they been formally approved by the Definition Subcommttee.

1. Current Amplification-The current amplification of a magnetic amplifier is the ratio of the change in output current to the change in current in the control winding required to produce the output current change.

2. Figure of Merit-The figure of merit of a magnetic amplifier is the ratio of power amplification to the response time, preferably expressed in seconds.

3. Power Amplification-The power amplification of a magnetic amplifier is the product of the voltage amplification and the current amplification.

4. Voltage Amplification-The voltage amplification of a magnetic amplifier is the ratio of the change in output voltage to the change of voltage across the control winding circuit required to produce the output voltage change.

Document History

433
February 9, 2022
Recommended Practice for Insulation Testing of AC Electric Machinery with High Voltage Rating up to 30 kV at Very Low Frequency
This document describes very low frequency (VLF) testing of ac electric machines. It covers acceptance testing of new machines in the factory or on-site after erection. Also covered is the routine...
December 9, 2009
Recommended Practice for Insulation Testing of AC Electric Machinery with High Voltage at Very Low Frequency
This document describes very low frequency (VLF) testing of ac electric machines. It covers acceptance testing of new machines in the factory or on-site after erection. Also covered is the routine...
January 1, 1974
Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Voltage at Very Low Frequency
A description is not available for this item.
IEEE 433
January 1, 1959
Proposed Test Procedure for MAGNETIC AMPLIFIERS
FOREWORD The magnetic amplifier definitions contained in A I E E Transactions Paper No. 58-175 are adhered to. In addition, the following definitions are presented for clarity only; they are not a...