scope:

This guide is intended to provide a basis for synthetic testing of circuit breakers (see ANSI/IEEEC37.04-1979 [2]) and to establish the criteria for testing to demonstrate the short-circuit current rating of circuit breakers on a single phase basis.

It is recognized that other test requirements exist (such as capacitor switching, or line dropping) but they will be reserved for future consideration.

The guide contains typical circuits for demonstrating interrupting capability. These circuits are those in general use and their inclusion should not exclude the development of additional circuits to demonstrate specific capabilities.

The purpose of this guide is to establish criteria for synthetic testing and for the proper evaluation of results. Such criteria will establish validity of the test method without imposing restraints on innovation and improvement of test circuitry.

Document History

December 9, 1997
Supplement to IEEE Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis 8.3.2: Recovery Voltage for Terminal Faults; Asymmetrical Short-Circuit Current
Introduction (This introduction is not part of IEEE Std C37.081a-1997, Supplement to IEEE Guide for Synthetic Fault Testing of AC High- Voltage Circuit Breakers Rated on a Symmetrical Current...
December 9, 1997
Supplement to IEEE Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis 8.3.2: Recovery Voltage for Terminal Faults; Asymmetrical Short-Circuit Current
Introduction (This introduction is not part of IEEE Std C37.081a-1997, Supplement to IEEE Guide for Synthetic Fault Testing of AC High- Voltage Circuit Breakers Rated on a Symmetrical Current...
IEEE C37.081
January 1, 1981
Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
This guide is intended to provide a basis for synthetic testing of circuit breakers (see ANSI/IEEEC37.04-1979 [2]) and to establish the criteria for testing to demonstrate the short-circuit current...
January 1, 1981
Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
This guide is intended to provide a basis for synthetic testing of circuit breakers (see ANSI/IEEEC37.04-1979 [2]) and to establish the criteria for testing to demonstrate the short-circuit current...

References

Advertisement