IEC TS 62600-102

Marine energy – Wave, tidal and other water current converters – Part 102: Wave energy converter power performance assessment at a second location using measured assessment data

active, Most Current
Buy Now
Organization: IEC
Publication Date: 1 August 2016
Status: active
Page Count: 38
ICS Code (Hydraulic energy engineering): 27.140
scope:

Wave Energy Converters (WEC) need to be designed to operate efficiently at different locations. Systematic methods should be used to evaluate the power performance of a WEC at a second location (hereinafter Location 2) based on power performance assessment at a first location (hereinafter Location 1). The degree of similarity of the measured WEC (WEC 1) and the metocean conditions at Location 1 to the secondary WEC (WEC 2) at Location 2 determine the methodology and the applicability of this technical specification.

This part of IEC 62600, which is a Technical Specification, describes the required methods and the required conditions to determine the power performance of the WEC 2 in Location 2, possibly at a different scale and with configuration changes to accommodate the new site conditions, in all cases based on measured power performance of WEC 1 in Location 1. This technical specification allows for assessment at Location 1 or Location 2 based on limited/incomplete data material, as long as this is accompanied by a validated numerical model or physical model and assessment of the uncertainty involved. Another key element is transparency in the assessment.

This technical specification includes:

a) Specification of data requirements needed from the original measurements at Location 1 including an assessment of the uncertainty involved (if based on limited/incomplete data material) in addition to those specified in IEC TS 62600-100 and IEC TS 62600-101.

b) Limitation on the changes that are allowed to the WEC and the specification of the location.

c) Wave data required at Location 2, as a minimum the requirements found in IEC TS 62600-101.

d) Development of the power matrix at Location 2.

e) Validation of the power matrix at Location 2.

f) Assessment of uncertainties in the derived performance parameters at Location 2.

g) Requirements for the allowable power performance transfer by geometric, kinematic and dynamic similarity.

h) Requirements for the allowable incorporation of additional empirical model data.

i) Requirements for the allowable incorporation of additional numerical model data.

The technical specification does not cover the following items:

j) The original data measurement at Location 1 (see IEC TS 62600-100).

k) Environmental concerns.

l) Operation and maintenance.

 

 

Document History

IEC TS 62600-102
August 1, 2016
Marine energy – Wave, tidal and other water current converters – Part 102: Wave energy converter power performance assessment at a second location using measured assessment data
Wave Energy Converters (WEC) need to be designed to operate efficiently at different locations. Systematic methods should be used to evaluate the power performance of a WEC at a second location...

References