UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

ASTM International - ASTM E1590-16

Standard Test Method for Fire Testing of Mattresses

inactive
Buy Now
Organization: ASTM International
Publication Date: 15 November 2016
Status: inactive
Page Count: 24
ICS Code (Ignitability and burning behaviour of materials and products): 13.220.40
ICS Code (Furniture): 97.140
significance And Use:

5.1 This test method provides a means of measuring a variety of fire-test-response characteristics resulting from burning a test specimen, mattress or mattress with foundation. After ignition... View More

scope:

1.1 This is a fire-test-response standard.

1.2 This test method provides a means of determining the burning behavior of mattresses used in public occupancies by measuring specific fire test responses when the test specimen, a mattress or mattress with foundation, is subjected to a specified flaming ignition source under well ventilated conditions.

1.3 This is a test method for mattresses or mattresses with foundations.

1.4 Test data are obtained describing the burning behavior, following application of a specific ignition source, from ignition until all burning has ceased, a period of 1 h has elapsed, or flashover appears inevitable.

1.5 This test method does not provide information on the fire performance of mattresses under fire conditions other than those specified in this test method. In particular, this test method does not apply to smoldering ignition by cigarettes. See 5.12 for further information.

1.6 The rate of heat release of burning test specimen is measured by an oxygen consumption method. See 5.12.4 for further information.

1.7 Other measurements are the production of light-obscuring smoke and the concentrations of certain toxic gas species in the combustion gases. See 5.12.5 for further information.

1.8 The burning behavior is documented visually by photographic or video recordings.

1.9 Use the SI system of units in referee decisions; see IEEE/ASTM SI-10. The units given in parentheses are for information only.

1.10 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions

1.11 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

February 1, 2023
Standard Test Method for Fire Testing of Mattresses
5.1 This test method provides a means of measuring a variety of fire-test-response characteristics resulting from burning a test specimen, mattress or mattress with foundation. After ignition using a...
January 15, 2022
Standard Test Method for Fire Testing of Mattresses
5.1 This test method provides a means of measuring a variety of fire-test-response characteristics resulting from burning a test specimen, mattress or mattress with foundation. After ignition using a...
March 1, 2017
Standard Test Method for Fire Testing of Mattresses
5.1 This test method provides a means of measuring a variety of fire-test-response characteristics resulting from burning a test specimen, mattress or mattress with foundation. After ignition using a...
ASTM E1590-16
November 15, 2016
Standard Test Method for Fire Testing of Mattresses
5.1 This test method provides a means of measuring a variety of fire-test-response characteristics resulting from burning a test specimen, mattress or mattress with foundation. After ignition using a...
April 1, 2013
Standard Test Method for Fire Testing of Mattresses
5.1 This test method provides a means of measuring a variety of fire-test-response characteristics resulting from burning a test specimen, mattress or mattress with foundation. After ignition using a...
April 1, 2012
Standard Test Method for Fire Testing of Mattresses
This test method provides a means of measuring a variety of fire-test-response characteristics resulting from burning a test specimen, mattress or mattress with foundation. After ignition using a...
May 1, 2007
Standard Test Method for Fire Testing of Mattresses
1.1 This is a fire-test-response standard. 1.2 This test method provides a means of determining the burning behavior of mattresses used in public occupancies by measuring specific fire test responses...
September 10, 2002
Standard Test Method for Fire Testing of Mattresses
1.1 This is a fire-test-response standard. 1.2 This test method provides a means of determining the burning behavior of mattresses used in public occupancies by measuring specific fire test responses...
January 10, 2001
Standard Test Method for Fire Testing of Mattresses
1.1 This is a fire-test-response standard. 1.2 This test method provides a means of determining the burning behavior of mattresses used in public occupancies by measuring specific fire test responses...
January 10, 2001
Standard Test Method for Fire Testing of Mattresses
1.1 This is a fire-test-response standard. 1.2 This test method provides a means of determining the burning behavior of mattresses used in public occupancies by measuring specific fire test responses...
Advertisement