UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

AAMI TIR13004

Sterilization of health care products-Radiation-Substantiation of a selected sterilization dose: Method VDmax SD

active, Most Current
Buy Now
Organization: AAMI
Publication Date: 3 September 2013
Status: active
Page Count: 85
scope:

Inclusions

This Technical Specification describes a method for substantiating a selected sterilization dose of 17.5, 20, 22.5, 27.5, 30, 32.5 or 35 kGy that achieves a sterility assurance level (SAL) of 10−6 or less for radiation sterilization of health care products. This Technical Specification also specifies a method of sterilization dose audit used to demonstrate the continued effectiveness of the substantiated sterilization dose.

NOTE Selection and substantiation of the sterilization dose is used to meet the requirements for establishing the sterilization dose within process definition in ISO 11137-1.

Exclusions

This method is for the substantiation of a selected sterilization dose of 17.5, 20, 22.5, 27.5, 30, 32.5, or 35 kGy only and is not used to substantiate other sterilization doses. The method is not used for the substantiation of a selected sterilization dose if the average bioburden of the entire product item exceeds the limit specified for the selected sterilization dose.

NOTE The methods for substantiation of selected sterilization doses of 25 kGy and 15 kGy are not included in this Technical Specification; they are described in ISO 11137-2.

Application

If the decision is made to use this method of sterilization dose establishment, the method is to be followed according to the requirements (shall) and guidance (should) stipulated herein.

Document History

AAMI TIR13004
September 3, 2013
Sterilization of health care products-Radiation-Substantiation of a selected sterilization dose: Method VDmax SD
Inclusions This Technical Specification describes a method for substantiating a selected sterilization dose of 17.5, 20, 22.5, 27.5, 30, 32.5 or 35 kGy that achieves a sterility assurance level...
September 3, 2013
Sterilization of health care products — Radiation — Substantiation of a selected sterilization dose: Method VDmax SD
Inclusions This Technical Specification describes a method for substantiating a selected sterilization dose of 17.5, 20, 22.5, 27.5, 30, 32.5 or 35 kGy that achieves a sterility assurance level...

References

Advertisement