UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

NEN-EN 328

Heat exchangers - Forced convection unit air coolers for refrigeration - Test procedures for establishing the performance

active, Most Current
Organization: NEN
Publication Date: 1 September 2014
Status: active
Page Count: 51
ICS Code (Boilers and heat exchangers): 27.060.30
ICS Code (Ventilators. Fans. Air-conditioners): 23.120
scope:

NEN-EN 328 is applicable to non-ducted unit air coolers for refrigeration operating: a) with direct dry expansion of a refrigerant; b) with liquid overfeed by pump circulation of a refrigerant; c) with a liquid. This standard specifies uniform methods of performance assessment to test and ascertain the following: - product identification; - standard capacity; - standard liquid pressure drop; - standard refrigerant pressure drop (for operation with liquid overfeed by pump circulation only); - nominal air flow rate; - nominal fan power. It does not cover evaluation of conformity. It is not applicable to air coolers for duct mounting or with natural air convection. This standard does not cover technical safety aspects.

Document History

NEN-EN 328
September 1, 2014
Heat exchangers - Forced convection unit air coolers for refrigeration - Test procedures for establishing the performance
NEN-EN 328 is applicable to non-ducted unit air coolers for refrigeration operating: a) with direct dry expansion of a refrigerant; b) with liquid overfeed by pump circulation of a refrigerant; c)...
November 1, 2012
Heat exchangers - Forced convection unit air coolers for refrigeration - Test procedures for establishing the performance
NEN-EN 328 is applicable to non-ducted unit air coolers for refrigeration operating: a) with direct dry expansion of a refrigerant; b) with liquid overfeed by pump circulation of a refrigerant; c)...
November 1, 2002
Heat exchangers - Test procedure for establishing the performance of forced convection unit air coolers for refrigeration
A description is not available for this item.
May 1, 1999
Heat exchangers - Test procedures for establishing the performance of forced convection unit air coolers for refrigeration
Is applicable to non-ducted unit air coolers for refrigeration operating: a) with direct dry expansion of a refrigerant b) with liquid overfeed by pump circulation of a refrigerant c) with a liquid.

References

Advertisement