NEN-EN-IEC 60079-14

Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines)

inactive
Organization: NEN
Publication Date: 1 September 2003
Status: inactive
Page Count: 138
ICS Code (Electrical apparatus for explosive atmospheres): 29.260.20
scope:

This part of IEC 60079 contains the specific requirements for the design, selection and erection of electrical installations in explosive gas atmospheres. These requirements are in addition to the requirements for installations in non-hazardous areas. This standard applies to all electrical equipment and installations in hazardous areas whether permanent, temporary, portable, transportable or hand-held. It applies to installations at all voltages.

Document History

April 1, 2016
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
A description is not available for this item.
April 1, 2014
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
NEN-EN-IEC 60079-14 contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associated with, explosive atmospheres. Where the...
November 1, 2011
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
A description is not available for this item.
November 1, 2008
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
This part of IEC 60079 contains the specific requirements for the design, selection and erection of electrical installations in hazardous areas associated with explosive atmospheres. Where the...
NEN-EN-IEC 60079-14
September 1, 2003
Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines)
This part of IEC 60079 contains the specific requirements for the design, selection and erection of electrical installations in explosive gas atmospheres. These requirements are in addition to the...
April 1, 2001
Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines)
Contains specific requirements for the design, selection and erection of electrical installations in explosive gas atmospheres. These requirements apply additionally to the requirements for...