NEN-EN 868-6
Packaging materials and systems for medical devices which are to be sterilized - Part 6: Paper for the manufacture of packs for medical use for sterilization by ethylene oxide or irradiation - Requirements and test methods
inactive
| Organization: | NEN |
| Publication Date: | 1 July 1999 |
| Status: | inactive |
| Page Count: | 17 |
| ICS Code (Packaging materials and accessories): | 55.040 |
| ICS Code (Sterilization and disinfection): | 11.080 |
scope:
Provides examples of particular requirements and test methods for paper used in the manufacture of packs for medical use. It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards.
Document History
February 1, 2017
Packaging for terminally sterilized medical devices - Part 6: Paper for low temperature sterilization processes - Requirements and test methods
NEN-EN 868-6 specifies test methods and values for paper used in the manufacture of preformed sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally...
August 1, 2015
Packaging for terminally sterilized medical devices - Part 6: Paper for low temperature sterilization processes - Requirements and test methods
NEN-EN 868-6 specifies test methods and values for paper used in the manufacture of preformed sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally...
June 1, 2009
Packaging for terminally sterilized medical devices - Part 6: Paper for low temperature sterilization processes - Requirements and test methods
This part of EN 868 provides test methods and values for paper used in the manufacture of preformed sterile barrier systems and/or packaging systems that are intended to maintain sterility of...
September 1, 2007
Packaging materials for terminally sterilized medical devices - Part 6: Paper for the manufacture of sterile barrier systems intended for sterilization by low temperature sterilization process or irradiation - Requirements and test methods
This part of EN 868 provides test methods and values for paper used in the manufacture of preformed sterile barrier systems and/or packaging systems that are intended to maintain sterility of...
NEN-EN 868-6
July 1, 1999
Packaging materials and systems for medical devices which are to be sterilized - Part 6: Paper for the manufacture of packs for medical use for sterilization by ethylene oxide or irradiation - Requirements and test methods
Provides examples of particular requirements and test methods for paper used in the manufacture of packs for medical use. It introduces no additional requirements to the general requirements of Part...
July 1, 1997
Packaging materials and systems for medical devices which are to be sterilized - Part 6: Paper for the manufacture of packs for medical use for sterilization by ethylene oxide or irradiation - Requirements and test methods
Provides examples of particular requirements and test methods for paper used in the manufacture of packs for medical use. It introduces no additional requirements to the general requirements of Part...