UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

NEN-EN 13725

Air quality - Determination of odour concentration by dynamic olfactometry

inactive
Organization: NEN
Publication Date: 1 September 2003
Status: inactive
Page Count: 74
ICS Code (Other standards related to air quality): 13.040.99
scope:

This European Standard specifies a method for the objective determination of the odour concentration of a gaseous sample using dynamic olfactometry with human assessors and the emission rate of odours emanating from point sources, area sources with outward flow and area sources without outward flow. The primary application is to provide a common basis for evaluation of odour emissions in the member states of the European Union. This European Standard is applicable to the measurement of odour concentration of pure substances, defined mixtures and undefined mixtures of gaseous odorants in air or nitrogen, using dynamic olfactometry with a panel of human assessors being the sensor. The unit of measurement is the European odour unit per cubic metre: ouE/m3. The odour concentration is measured by determining the dilution factor required to reach the detection threshold. The odour concentration at the detection threshold is by definition 1 ouE/m3. The odour concentration is then expressed in terms of multiples of the detection threshold. The range of measurement is typically from 101 ouE/m3 to 107 ouE/m3 (including pre-dilution). The field of application of this European Standard includes: - the measurement of the mass concentration at the detection threshold of pure odorous substances in g/m3; - the measurement of the odour concentration of mixtures of odorants in ouE/m3; - the measurement of the emission rate of odorous emissions from point sources and surface sources (with and without an outward flow), including pre-dilution during sampling; - the sampling of odorants from emissions of high humidity and temperature (up to 200 °C); - the determination of effectiveness of end-of-pipe devices used to reduce odour emissions. The characterisation of odour emissions requires detailed measurement of the gas velocity, that shall be performed according to the relevant standards included in the normative references.

Document History

March 1, 2022
Stationary source emissions - Determination of odour concentration by dynamic olfactometry and odour emission rate
This document specifies an objective method for the determination of the odour concentration of a gaseous sample using dynamic olfactometry with human assessors. The document also specifies a method...
July 1, 2019
Stationary source emissions - Determination of odour concentration by dynamic olfactometry and odour emission rate from stationary sources
This document specifies a method for the objective determination of the odour concentration of a gaseous sample using dynamic olfactometry with human assessors. The standard also specifies a method...
October 1, 2006
Air quality - Determination of odour concentration by dynamic olfactometry
A description is not available for this item.
NEN-EN 13725
September 1, 2003
Air quality - Determination of odour concentration by dynamic olfactometry
This European Standard specifies a method for the objective determination of the odour concentration of a gaseous sample using dynamic olfactometry with human assessors and the emission rate of...
October 1, 1999
Air quality - Determination of odour concentration by dynamic olfactometry
This European Standard specifies a method for the objective determination of the odour concentration of a gaseous sample using dynamic olfactometry with human assessors and the emission rate of...

References

Advertisement