NEN-EN 13160-4

Leak detection systems - Part 4: Requirements and test/assessment methods for sensor based leak detection systems

active, Most Current
Organization: NEN
Publication Date: 1 July 2016
Status: active
Page Count: 41
ICS Code (Other pipeline components): 23.040.99
ICS Code (Fluid storage devices in general): 23.020.01
ICS Code (Electrical apparatus for explosive atmospheres): 29.260.20
scope:

NEN-EN 13160-4 gives requirements and the corresponding test/assessment methods applicable to sensor based leak detection systems (leak detection kits). The leak detection kits are intended to be used in interstitial spaces, leakage containments or monitoring wells. The leak detection kits are usually composed by: - sensing device(s); - evaluation device; - alarm device.

Document History

NEN-EN 13160-4
July 1, 2016
Leak detection systems - Part 4: Requirements and test/assessment methods for sensor based leak detection systems
NEN-EN 13160-4 gives requirements and the corresponding test/assessment methods applicable to sensor based leak detection systems (leak detection kits). The leak detection kits are intended to be...
September 1, 2014
Leak detection systems - Part 4: Requirements and test/assessment methods for sensor based leak detection systems
NEN-EN 13160-4 gives requirements and the corresponding test/assessment methods applicable to sensor based leak detection systems (leak detection kits). The leak detection kits are intended to be...
July 1, 2003
Leak detection systems - Part 4: Liquid and/or vapour sensor systems for use in leakage containments or interstitial spaces
This European Standard specifies the requirements for leak detection systems - class III for use in the interstitial space of double-skin systems or in leakage containments of single skin systems...
March 1, 1998
Leak detection systems - Part 4: Liquid and/or vapour sensor systems for use in leakage containments or interstitial spaces
This European Standard specifies the requirements for leak detection systems - class III for use in the interstitial space of double-skin systems or in leakage containments of single skin systems...