NEN-EN-IEC 61290-3-2

Optical amplifiers - Test methods - Part 3-2: Noise figure parameters - Electrical spectrum analyzer method

active, Most Current
Organization: NEN
Publication Date: 1 November 2008
Status: active
Page Count: 29
ICS Code (Optic amplifiers): 33.180.30
scope:

This part of IEC 61290 applies to all commercially available optical amplifiers (OAs), including OAs using optically pumped fibres (OFAs based on either rare-earth doped fibres or on the Raman effect), semiconductor optical amplifiers (SOAs) and planar waveguide optical amplifiers (PWOAs). The object of this standard is to establish uniform requirements for accurate and reliable measurements, by means of the electrical spectrum analyzer (ESA) method, of the noise figure, as defined in IEC 61291-1. The present test method is based on direct electrical noise measurement and it is directly related to its definition including all relevant noise contributions. Therefore, this method can be used for all types of optical amplifiers, including SOA and Raman amplifiers which can have significant contributions besides amplified spontaneous emission, because it measures the total noise figure. For further details of applicability, see IEC 61290-3. An alternative test method based on the optical spectrum analyzer can be used, particularly for different noise parameters (such as the signal-spontaneous noise factor) but it is not included in the object of this standard.

Document History

NEN-EN-IEC 61290-3-2
November 1, 2008
Optical amplifiers - Test methods - Part 3-2: Noise figure parameters - Electrical spectrum analyzer method
This part of IEC 61290 applies to all commercially available optical amplifiers (OAs), including OAs using optically pumped fibres (OFAs based on either rare-earth doped fibres or on the Raman...
March 1, 2003
Optical amplifiers - Part 3-2: Test methods for noise figure parameters - Electrical spectrum analyser test method
Applies to optical fibre amplifiers (OFA) using active fibres, containing rare-earth dopants, presently commercially available. The object of this record is to establish uniform requirements for...