UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

NEN-EN 12158-2+A1

Builders' hoists for goods - Part 2: Inclined hoists with non-accessible load carrying devices

active, Most Current
Organization: NEN
Publication Date: 1 August 2010
Status: active
Page Count: 43
ICS Code (Lifts. Escalators): 91.140.90
scope:

This standard deals with power operated temporarily installed builders hoists intended for use by persons who are permitted to enter sites of engineering and construction, serving either one upper landing or a work area extending to the end of the guides, (e.g. a roof) having a load carrying device (lcd): - which is intended for the transportation of goods only; - where it is forbidden for persons to step upon it at any time; - which is guided; - which is designed to travel at an angle of at least 30 degrees to the vertical but may be used at any angle between the vertical and the maximum inclination as specified by the manufacturer; - which is sustained by steel wire rope and a positive drive system; - which is controlled by hold-to-run controls by the operator; - which does not benefit from the use of any counterweight; - which has a maximum rated load of 300 kg; - which has a maximum speed of 1,00 m/s; and where the guides require support from separate structures. The standard identifies hazards as listed in clause 4, which arise during the various phases in the life of such equipment and describes methods for the elimination or reduction of these hazards when used as intended by the manufacturer. The safety requirements and/or measures of this standard deal with the design of the base frame, guide rails, lcd, drive unit, electrical and/or hydraulic installation and the control of the hoist. Included is the design of any guide rail support but not the design of the supporting structure (e.g. building or scaffold) and any ties. Other aspects such as base enclosure, the design of any concrete, hard core, timber or other foundation arrangement, hoistway protection and the upper landing are dealt with in the users' manual section of this standard.

Document History

NEN-EN 12158-2+A1
August 1, 2010
Builders' hoists for goods - Part 2: Inclined hoists with non-accessible load carrying devices
This standard deals with power operated temporarily installed builders hoists intended for use by persons who are permitted to enter sites of engineering and construction, serving either one upper...
February 1, 2010
Builders hoists for goods - Part 2: Inclined hoists with non-accessible load carrying devices
A description is not available for this item.
November 1, 2000
Builders hoists for goods - Part 2: Inclined hoists with non-accessible load carrying devices
This standard deals with power operated temporarily installed builders hoists intended for use by persons who are permitted to enter sites of engineering and construction, serving either one upper...
November 1, 2000
Builders hoists for goods - Part 2: Inclined hoists with non-accessible load carrying devices
This standard deals with power operated temporarily installed builders hoists intended for use by persons who are permitted to enter sites of engineering and construction, serving either one upper...
October 1, 1995
Builders hoist for the transport of goods - Part 2: Inclined hoists with non-accessible load carrying devices
This standard deals with power operated temporarily installed builders hoists intended for use by persons who are permitted to enter sites of engineering and construction, serving either one upper...

References

Advertisement