ICS Code (Refrigerating technology): 27.200
scope:

NEN-EN 13215 specifies the rating conditions, tolerances and presentation of manufacturer's performance data for condensing units for refrigeration with compressors of the positive-displacement type. These include single stage compressors and single and two stage compressors having an integrated means of fluid sub cooling. This is required so that a comparison of different condensing units can be made. The data relate to the refrigerating capacity and power absorbed and include requirements for part-load performance where applicable.

Document History

December 1, 2016
Condensing units for refrigeration - Rating conditions, tolerances and presentation of manufacturer's performance data
NEN-EN 13215 specifies the rating conditions, tolerances and presentation of manufacturer's performance data for condensing units for refrigeration with compressors of the positive-displacement type....
NEN-EN 13215
July 1, 2015
Condensing units for refrigeration - Rating conditions, tolerances and presentation of manufacturer's performance data
NEN-EN 13215 specifies the rating conditions, tolerances and presentation of manufacturer's performance data for condensing units for refrigeration with compressors of the positive-displacement type....
April 1, 2000
Condensing units for refrigeration - Rating conditions, tolerances and presentation of manufacturer's performance data
Specifies the rating conditions, tolerances and presentation of manufacturer's performance data for single-stage condensing units for refrigeration with compressors of the positive-displacement type....
June 1, 1998
Condensing units for refrigeration - Rating conditions, tolerances and presentation of performance data
Specifies the rating conditions, tolerances and presentation of manufacturer's performance data for single-stage condensing units for refrigeration with compressors of the positive-displacement type....