NEN-EN 13146-5

Railway applications - Track - Test methods for fastening systems - Part 5: Determination of electrical resistance

inactive
Organization: NEN
Publication Date: 1 November 2009
Status: inactive
Page Count: 10
ICS Code (Construction of railways): 93.100
scope:

This European Standard specifies a laboratory test procedure for determining the electrical resistance, in wet conditions, between the running rails provided by a fastening system fitted to a steel or concrete sleeper, bearer or element of slab track. It is also applicable to embedded rail. This test procedure applies to a complete fastening assembly. It is relevant to signalling currents, not to traction currents. A reference procedure and an alternative procedure are included.

Document History

April 1, 2012
Railway applications - Track - Test methods for fastening systems - Part 5: Determination of electrical resistance
This European Standard specifies a laboratory test procedure for determining the electrical resistance, in wet conditions, between the running rails provided by a fastening system fitted to a steel...
NEN-EN 13146-5
November 1, 2009
Railway applications - Track - Test methods for fastening systems - Part 5: Determination of electrical resistance
This European Standard specifies a laboratory test procedure for determining the electrical resistance, in wet conditions, between the running rails provided by a fastening system fitted to a steel...
December 1, 2002
Railway applications - Track - Test methods for fastening systems - Part 5: Determination of electrical resistance
Specifies a laboratory test procedure for determining the electrical resistance, in wet conditions, between the running rails provided by a fastening system fitted to a steel or concretesleeper,...
April 1, 1998
Railway applications - Track - Test methods for fastening systems - Part 5: Determination of electrical resistance
Specifies a laboratory test procedure for determining the electrical resistance, in wet conditions, between the running rails provided by a fastening system fitted to a steel or concretesleeper,...