ASA - ANSI/ASA S12.6
American National Standard Methods for Measuring the Real-Ear Attenuation of Hearing Protectors
| Organization: | ASA |
| Publication Date: | 3 September 2008 |
| Status: | inactive |
| Page Count: | 48 |
scope:
This standard specifies laboratory-based procedures for measuring, analyzing, and reporting the passive noise-reducing capacity of hearing protection devices. The methods consist of psychophysical tests conducted on human subjects to determine real-ear attenuation at threshold.
Two methods are provided, differing in their subject selection,
training, hearing protector fitting procedures, and experimenter
involvement, but corresponding in all electroacoustic and
psychophysical aspects. One method, designated trained-subject
fit, is intended to describe the upper limits of hearing
protector performance for devices fitted by carefully trained
users. The second method, designated inexperienced-subjec
Applications
The selection of test method, trained-subject fit or
inexperienced-subjec
Method-A trained-subject fit will correspond most closely to tests using the prior versions of this standard, issued in 1984 and 1997, and its predecessor, ANSI S3.19-1974. Such values are useful to estimate performance for highly trained and motivated individual users, as well as in the design of hearing protectors, to provide a theoretical understanding of their performance limitations, and for routine testing for quality assurance purposes.
Method-B inexperienced-subjec
Regardless of the test method that is selected, trained-subject
fit or inexperienced-subjec
(a) the hearing protectors are worn in practice in the same manner as during the laboratory test;
(b) the hearing protectors are properly maintained; and
(c) the anatomical characteristics of the population of actual wearers are a reasonable match to the laboratory test subjects.
The methods of this standard apply to passive hearing protectors, as well as to electronic devices when the electronics are turned off. Hearing protectors can also take the form of communications headsets and earplugs, helmets, pressure suits, and other systems with sound-attenuating features. Devices can be used in combination with one another, such as earplugs worn in conjunction with earmuffs or helmets.
The methods of this standard yield data that are collected at low sound pressure levels (close to the threshold of hearing) but which are also representative of the attenuation values of hearing protectors at higher levels. One exception occurs in the case of passive amplitude-sensitive hearing protectors for sound pressure levels above the point at which their level-dependent characteristics become effective. At those levels the methods specified in this standard are inapplicable; they will usually underestimate sound attenuation (Berger, 1986). Another exception exists with respect to predicting the noise reduction of high-level impulsive sounds such as from weapons fire, over 140 dB peak sound pressure level, because of possible level-dependent behavior of hearing protectors when exposed to such sounds.
The low-frequency (below 500 Hz) real-ear attenuation at threshold data resulting from this standard may be spuriously high by a few decibels, with the error increasing as frequency decreases. This results from masking of the occluded-ear thresholds caused by physiological noise during testing (Berger and Kerivan, 1983; Schroeter and Poesselt, 1986). The errors are largest for semi-insert and supra-aural hearing protectors, for small-volume earmuffs, and for shallowly inserted earplugs. The errors are smallest for large-volume earmuffs and more deeply inserted earplugs.
This standard does not address issues pertaining to computation of protected noise exposures or rating systems for applying hearing protector attenuation values (see ANSI/ASA S12.68), nor does it specify minimum performance values for hearing protectors, or address comfort or wearability features.