DS/EN 15423

Ventilation for buildings - Fire precautions for air distribution systems in buildings

active, Most Current
Buy Now
Organization: DS
Publication Date: 2 June 2008
Status: active
Page Count: 26
ICS Code (Ventilation and air-conditioning systems): 91.140.30
ICS Code (Fire protection): 13.220.20
scope:

This document gives guidance for system designers, installers, commissioners and maintenance teams on the incorporation of protective measures for air distribution systems including dual purpose systems for smoke and heat exhaust systems within buildings, to prevent the initiation and the spread of fire, smoke and other by-products of combustion.
This document intends to only support any national (building) regulations, which are the basis of any design of a building or parts of it. It is up to the designer to enquire about the suitability (in particular in legal terms) of a specific solution given in this document (e.g. although ""dual purpose systems"" are covered in this document, they may not be permitted in some Member States or only in certain types of buildings).
This document applies to all air distribution systems including dual purpose systems (except systems only dedicated to smoke exhaust systems, which are dealt in other European standards) including technical rooms or spaces for the installation of devices to assist in ventilation of a building (e.g. distance of storage of combustible materials to devices and not the fire resistance of the building structure), penetrations, and following components/products used in the system like:
- inlet/outlet louvres;
- fans not exposed / exposed to the smoke;
- air control dampers;
- ducts;
- fire control dampers;
- air terminal devices;
- anchors and supports;
- duct fittings;
- control panels;
- cables and connections;
- air handling units;
- air filters;
- sound attenuators;
- heat exchangers.

Document History

DS/EN 15423
June 2, 2008
Ventilation for buildings - Fire precautions for air distribution systems in buildings
This document gives guidance for system designers, installers, commissioners and maintenance teams on the incorporation of protective measures for air distribution systems including dual purpose...
January 1, 2006
Ventilation for buildings - Fire precautions for air distribution systems in buildings
A description is not available for this item.
Advertisement