NASA-LLIS-0436

Lessons Learned - Receiver 1 Power Converter Failure on Voyager 2 (1978)

active, Most Current
Organization: NASA
Publication Date: 17 July 1996
Status: active
Page Count: 4
scope:

Abstract:

A Voyager telemetry failure was attributed to over-length screws that caused conductive end-caps to contact areas not sufficiently coated by conformal coating. The lesson provides recommendations for design of captivated inserts, QA monitoring of assembly, application of conformal coatings, and planning of ground activities.

Document History

NASA-LLIS-0436
July 17, 1996
Lessons Learned - Receiver 1 Power Converter Failure on Voyager 2 (1978)
Abstract: A Voyager telemetry failure was attributed to over-length screws that caused conductive end-caps to contact areas not sufficiently coated by conformal coating. The lesson provides...