Description of Driving Event:

General purpose computer S/N 00513 at the JAEL test facility operated for 11.5 hours without cooling. The lack of forced air ventilation was caused by an air duct cover left on during installation.

According to personnel working in JAEL and the results of JAEL's investigation, the factors which contributed to the problem were inadequate supervision of individuals involved, a lack of discipline in the practice of handling flight equipment, and failure of JAEL and quality assurance personnel to follow and/or verify existing procedures.

Document History

NASA-LLIS-0259
March 8, 1993
Lessons Learned - Vacuum Detection Systems
Description of Driving Event: General purpose computer S/N 00513 at the JAEL test facility operated for 11.5 hours without cooling. The lack of forced air ventilation was caused by an air duct cover...