NASA-LLIS-0280

Lessons Learned – Galileo Power Subsystem Internal Voltage Drop

active, Most Current
Organization: NASA
Publication Date: 12 July 1993
Status: active
Page Count: 2
scope:

Abstract:

The high resistivity of nickel ribbon used for electrical interconnections within power modules caused excessive voltage drops at subsystem power interfaces.

Voltage drop analyses should be conducted to assure that voltages at the subsystem power distribution interfaces will always remain within the specified tolerances. Perform early subsystem bench level tests using representative external interface circuits to verify adequate performance.

Document History

NASA-LLIS-0280
July 12, 1993
Lessons Learned – Galileo Power Subsystem Internal Voltage Drop
Abstract: The high resistivity of nickel ribbon used for electrical interconnections within power modules caused excessive voltage drops at subsystem power interfaces. Voltage drop analyses should...