NASA-LLIS-0100

Lessons Learned - Silver Zinc Battery

active, Most Current
Organization: NASA
Publication Date: 7 August 1992
Status: active
Page Count: 2
scope:

Description of Driving Event:

Two employees received caustic electrolyte exposure of hands during removal of two batteries from containers for installation in the ET. Installation was to support OMI S0008. Immediate cleanup procedures were initiated and area cordoned off. Personnel contamination was neutralized and employees reported to medical facility for evaluation. Batteries were relocated to the battery lab. Batteries are of a new design still under qualification testing. Four batteries had been activated, two were installed on the SRB's, the two ET batteries were maintained at ambient temperatures until the time of the incident.

Document History

NASA-LLIS-0100
August 7, 1992
Lessons Learned - Silver Zinc Battery
Description of Driving Event: Two employees received caustic electrolyte exposure of hands during removal of two batteries from containers for installation in the ET. Installation was to support OMI...