NASA-LLIS-1383

Lessons Learned – Autoclave Purge Blower Failure

active, Most Current
Organization: NASA
Publication Date: 14 October 2003
Status: active
Page Count: 3
scope:

Abstract:

A mishap occurred in a large (18' X 20') autoclave resulting in damage to government property of approximately $23K. The mishap was likely the result of a small amount of accumulated debris around a pneumatic valve, coupled with a minor error in pressure system logic, which failed to alert operators of the event prior to failure.

Document History

NASA-LLIS-1383
October 14, 2003
Lessons Learned – Autoclave Purge Blower Failure
Abstract: A mishap occurred in a large (18' X 20') autoclave resulting in damage to government property of approximately $23K. The mishap was likely the result of a small amount of accumulated...