Lessons Learned - Quench Module Insert (QMI) Furnace Type C Thermocouple (TC) Assembly and Testing Lessons Learned

active, Most Current
Organization: NASA
Publication Date: 1 January 2005
Status: active
Page Count: 3
scope:

Abstract:

The QMI furnace required custom-designed Type C Thermocouples (TC) to meet the scientific requirements for the hardware. In implementing the custom requirement set and associated verification testing for these TCs notable anomalies/problems were encountered in two areas. The primary problem was the discovery of contamination (mostly Carbon deposits) on the inner surfaces of the TC that led to acceptance test failures. A secondary problem was caused by attempting to maximize the TC wire size yet limiting the overall TC sheath diameter leading to assembly problems of each TC.

Document History

NASA-LLIS-1512
January 1, 2005
Lessons Learned - Quench Module Insert (QMI) Furnace Type C Thermocouple (TC) Assembly and Testing Lessons Learned
Abstract: The QMI furnace required custom-designed Type C Thermocouples (TC) to meet the scientific requirements for the hardware. In implementing the custom requirement set and associated...