DLA - MIL-C-55021/2

CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 DEG. C

inactive
Organization: DLA
Publication Date: 10 December 1965
Status: inactive
Page Count: 4
scope:

This specification covers polytetrafluoroethylene insulated electrical hookup wire in twisted pair and triple combinations, both shielded and unshielded, for application in internal wiring of electrical md electronic equipment at temperatures from -40 degrees to 80 degrees C and from -65 degrees to 200 degrees C, with potential ratings from 600 to 1000 volts (rms) depending upon construction.

intended Use:

Cables covered by this specification are used in the hookup of various electronic assemblies. All cables are suitable for high frequency use. The shielded wires are used to provide a... View More

Document History

January 19, 2016
CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 DEGREES C
A description is not available for this item.
March 23, 2011
CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 Degrees C
This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification...
June 24, 2005
CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 DEG. C
A description is not available for this item.
August 11, 2000
CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 DEG. C
This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification...
April 16, 1991
CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 DEG. C
This Specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of the specification...
November 8, 1973
CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 DEG. C
A description is not available for this item.
MIL-C-55021/2
December 10, 1965
CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -65 TO 200 DEG. C
This specification covers polytetrafluoroethylene insulated electrical hookup wire in twisted pair and triple combinations, both shielded and unshielded, for application in internal wiring of...