DSF/prEN ISO 12569

Thermal performance of buildings and materials - Determination of specific airflow rate in buildings - Tracer gas dilution method (ISO/DIS 12569:2010)

pending
Organization: DS
Status: pending
Page Count: 66
ICS Code (Thermal insulation of buildings): 91.120.10
scope:

The specifications set forth an engineering standard by which to obtain the ventilation rate/specific airflow rate, using a tracer gas in a building space, which is considered to be of a single zone. 1) The measurement method is valid in spaces where the air is well mixed. In particular, there should be no large air flows such as cross-ventilation. 2) The specifications set forth as measurement methods using a tracer gas, three measurement methods: (1) Concentration decay method (2) Continuous dose method and (3) Constant concentration method. Note 1 In spaces where a large amount of ventilation such as cross-ventilation occurs, concentration is not uniformly distributed and large changes of concentration tend to occur over time, so they are not targeted. However, if the direction of flow is evident such as with flow within a duct, the specific airflow rate can be assessed using the continuous dose method. Note 2 The measuring accuracy of the so-called concentration raise method has a relatively poor accuracy and is seldom used, so will not be mentioned here.

Document History

January 9, 2013
Thermal performance of buildings and materials - Determination of specific airflow rate in buildings - Tracer gas dilution method
ISO 12569:2012 establishes an engineering standard by which to obtain the ventilation rate/specific airflow rate, using a tracer gas in a building space, which is considered to be of a single zone....
December 14, 2000
Thermal performance of buildings - Determination of air change in buildings - Tracer gas dilution method
This standard describes the use of tracer gas dilution for determining the air change in a single zone as induced by weather conditions or mechanical ventilation. The procedures for tracer gas...
Thermal performance of buildings and materials - Determination of specific airflow rate in buildings - Tracer gas dilution method (ISO/DIS 12569:2016)
This International Standard establishes an engineering standard by which to obtain the ventilation rate/specific airflow rate, using a tracer gas in a building space, which is considered to be of a...
Thermal performance of buildings and materials – Determination of specific airflow rate in buildings – Tracer gas dilution method (ISO/FDIS 12569:2017)
This International Standard establishes an engineering standard by which to obtain the ventilation rate/specific airflow rate, using a tracer gas in a building space, which is considered to be of a...
Thermal performance of buildings and materials - Determination of specific airflow rate in buildings - Tracer gas dilution method (ISO/FDIS 12569:2012)
This International Standard establishes an engineering standard by which to obtain the ventilation rate/specific airflow rate, using a tracer gas in a building space, which is considered to be of a...
DSF/prEN ISO 12569
Thermal performance of buildings and materials - Determination of specific airflow rate in buildings - Tracer gas dilution method (ISO/DIS 12569:2010)
The specifications set forth an engineering standard by which to obtain the ventilation rate/specific airflow rate, using a tracer gas in a building space, which is considered to be of a single zone....