DS/HD 60364-7-702

Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Swimming pools and fountains

active
Organization: DS
Publication Date: 18 October 2010
Status: active
Page Count: 26
ICS Code (Electricity supply systems): 91.140.50
scope:

IEC 60364-7-702:2010 applies to electrical installations of: - basins of swimming pools and paddling pools and their surrounding zones; - areas in natural waters, lakes in gravel pits and coastal and similar areas, specially intended to be occupied by persons for swimming, paddling and similar purposes, and their surrounding zones. Such areas in natural waters, lakes in gravel pits and coastal and similar areas, are considered as swimming pools; - basins of fountains and their surrounding zones. For swimming pools for medical use, special requirements may apply. This third edition cancels and replaces the second edition published in 1997 and constitutes a technical revision. The main changes with respect to the previous edition are as follows: - the scope has been improved, including natural areas in natural waters; - the description of zones has been improved; - all figures have been updated.

Document History

July 29, 2015
Low-voltage electrical installations – Part 7-702: Requirements for special installations or locations – Swimming pools and fountains
The particular requirements of this part of HD 60364 apply to electrical installations of: – basins of swimming pools and paddling pools and their surrounding zones; – areas in natural waters, lakes...
DS/HD 60364-7-702
October 18, 2010
Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Swimming pools and fountains
IEC 60364-7-702:2010 applies to electrical installations of: - basins of swimming pools and paddling pools and their surrounding zones; - areas in natural waters, lakes in gravel pits and coastal and...
Low-voltage electrical installations – Part 7-702: Requirements for special installations or locations – Swimming pools and fountains
Amendment on HD 60364-7-702, to cover proposal for modifications/amendments as received from CEN TC 402. Requires change of the existing scope
Low-voltage electrical installations -- Part 7-702: Requirements for special installations or locations - Swimming pools and fountains
To add the following: This part applies to electrical installations of: - basins of swimming and paddling pools and in their surrounding zones; - areas in natural waters, lakes in gravel pits and...
Low-voltage electrical installations -- Part 7-702: Requirements for special installations or locations - Swimming pools and fountains
To add the following: This part applies to electrical installations of: - basins of swimming and paddling pools and in their surrounding zones; - areas in natural waters, lakes in gravel pits and...
Low-voltage electrical installations -- Part 7-702: Requirements for special installations or locations - Swimming pools and fountains
The particular requirements of this part of IEC 60364 apply to electrical installations of: - basins of swimming pools and paddling pools and their surrounding zones; - areas in natural waters, lakes...