scope:

This standard describes the installation and maintenance procedures for wiring devices.

Products and Applications Included

This standard covers the installation and maintenance of wiring devices that are rated 600V and less that are intended to be permanently connected to building premises wiring systems on non-hazardous (unclassified) branch circuits for residential, commercial, and industrial applications for new installations, replacements in existing installations, and new branch-circuit extensions in existing installations. It applies to:

• Receptacles non-locking-type and locking type

• Multi-outlet assemblies

• Attachment plugs, connector bodies, and motor attachment plugs (inlets), (both non-lockingtype and locking-type)

• Pin-and-sleeve devices (Receptacles, Attachment plugs, connector bodies, and Motor attachment plugs (inlets))

• Switches

• Timers

• Combination devices

• Occupancy sensors

• Dimmers

• Coverplates and outlet box hoods

Products and Applications Excluded

This standard does not cover:

• Wiring devices installed in hazardous locations

• Wiring devices that are temporary installations

• Arc-Fault Circuit Interrupters (AFCIs) or Ground-Fault Circuit Interrupters (GFCIs). See NECA 169.

• Floor service outlets

• Floor poke-through assemblies

Regulatory and Other Requirements

All information in this publication is intended to conform to the NEC (ANSI/NFPA 70). Installers shall follow the NEC, applicable state and local codes, manufacturer instructions, and contract documents when installing and maintaining wiring devices.

Only qualified persons as defined in the NEC familiar with the construction, installation, and operation of wiring devices shall perform the technical work described in this publication. Administrative functions such as receiving, handling, and storing wiring devices and other tasks may be performed under the supervision of a qualified person. All work shall be performed in accordance with NFPA 70E, Standard for Electrical Safety in the Workplace.

General requirements for installing electrical products and systems are described in NECA 1, Standard for Good Workmanship in Electrical Construction (ANSI). Other NEIS provide additional guidance for installing particular types of electrical products and systems. A complete list of NEIS is provided in Annex C.

Mandatory Requirements, Permissive Requirements, Quality and Performance Recommendations, Explanatory Material, and Informative Annexes

Mandatory requirements in manufacturer instructions, or of Codes or other mandatory Standards that may or not be adopted into law, are those that identify actions that are specifically required or prohibited and are characterized by the use of the terms "must" or "must not," "shall" or "shall not," "may not," or "are not permitted," or "are required," or by the use of positive phrasing of mandatory requirements. Examples of mandatory requirements may equally take the form of, "equipment must be protected . . .," "equipment shall be protected . . .," or "protect equipment . . .," with the latter interpreted (understood) as "(it is necessary to) protect equipment . . ."

Permissive requirements of manufacturer instructions, or of Codes or other mandatory Standards that may or not be adopted into law, are those that identify actions that that are allowed but not required, or are normally used to describe options or alternative means and methods, and are characterized in this Standard by the use of the terms "may," or "are permitted," or "are not required."

Quality and performance recommendations identify actions that are recommended or not recommended to improve the overall quality or performance of the installation and are characterized by the use of the terms "should" or "should not."

Explanatory material, such as references to other Codes, Standards, or documents, references to related sections of this Standard, information related to another Code, Standard, or document, and supplemental application and design information and data, is included throughout this Standard to expand the understanding of mandatory requirements, permissive requirements, and quality and performance recommendations. Such explanatory material is included for information only, and is identified by the use of the term "NOTE," or by the use of italicized text.

Informative Annexes. Non-mandatory information and other reference standards or documents relative to the application and use of materials, equipment, and systems covered by this Standard are provided in informative annexes. Informative annexes are not part of the enforceable requirements of this Standard, but are included for information purposes only.

Document History

NECA NEIS 130
January 1, 2016
Standard for Installing and Maintaining Wiring Devices
This standard describes the installation and maintenance procedures for wiring devices. Products and Applications Included This standard covers the installation and maintenance of wiring devices...
January 1, 2010
Standard for Installing and Maintaining Wiring Devices
This standard describes the installation and maintenance procedures for wiring devices. Applications Included This standard covers the installation and maintenance of low-voltage wiring devices...

References

Advertisement