ASTM International - ASTM F1695-20

Standard Test Method for Performance of Underfired Broilers

active
Buy Now
Organization: ASTM International
Publication Date: 1 September 2020
Status: active
Page Count: 18
ICS Code (Cooking ranges, working tables, ovens and similar appliances): 97.040.20
significance And Use:

5.1 The energy input rate test is used to confirm that the underfired broiler is operating properly prior to further testing.

5.2 Temperature distribution of the broiling area may be used... View More

scope:

1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler and understand its energy performance.

1.2 This test method is applicable to gas and electric underfired broilers.

1.3 The underfired broiler can be evaluated with respect to the following (where applicable):

1.3.1 Energy input rate (see 10.2),

1.3.2 Temperature distribution across the broiling area (see 10.3),

1.3.3 Preheat energy and time (see 10.5),

1.3.4 Pilot energy rate, if applicable (see 10.6),

1.3.5 Cooking energy rate (see 10.7), and

1.3.6 Cooking energy efficiency and production capacity (see 10.8).

1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM F1695-20
September 1, 2020
Standard Test Method for Performance of Underfired Broilers
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler...
March 1, 2015
Standard Test Method for Performance of Underfired Broilers
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler...
October 1, 2008
Standard Test Method for Performance of Underfired Broilers
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler...
September 10, 2003
Standard Test Method for Performance of Underfired Broilers
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler...
September 10, 2003
Standard Test Method for Performance of Underfired Broilers
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler...
January 1, 1996
Standard Test Method for Performance of Underfired Broilers
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler...