ASTM International - ASTM E1949-03(2014)e1

Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 April 2009
Status: inactive
Page Count: 5
ICS Code (Mechanical testing): 19.060
significance And Use:

4.1 Strain gages are the most widely used devices for measuring strains and for evaluating stresses in structures. In many applications there are often cyclic loads which can cause strain gage... View More

scope:

1.1 This test method covers a uniform procedure for the determination of strain gage fatigue life at ambient temperature. A suggested testing equipment design is included.

1.2 This test method does not apply to force transducers or extensometers that use bonded resistance strain gages as sensing elements.

1.3 Strain gages are part of a complex system that includes structure, adhesive, gage, lead wires, instrumentation, and (often) environmental protection. As a result, many things affect the performance of strain gages, including user technique. A further complication is that strain gages, once installed, normally cannot be reinstalled in another location. Therefore, it is not possible to calibrate individual strain gages; performance characteristics are normally presented on a statistical basis.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.

Document History

February 1, 2021
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
1.1 This test method covers a uniform procedure for the determination of strain gage fatigue life at ambient temperature. A suggested testing equipment design is included. 1.2 This test method does...
April 15, 2014
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
4.1 Strain gages are the most widely used devices for measuring strains and for evaluating stresses in structures. In many applications there are often cyclic loads which can cause strain gage...
April 1, 2009
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
Strain gages are the most widely used devices for measuring strains and for evaluating stresses in structures. In many applications there are often cyclic loads which can cause strain gage failure....
ASTM E1949-03(2014)e1
April 1, 2009
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
4.1 Strain gages are the most widely used devices for measuring strains and for evaluating stresses in structures. In many applications there are often cyclic loads which can cause strain gage...
September 10, 2003
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
Strain gages are the most widely used devices for measuring strains and for evaluating stresses in structures. In many applications there are often cyclic loads which can cause strain gage failure....
April 10, 2002
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
1.1 This test method covers a uniform procedure for the determination of strain gage fatigue life at ambient temperature. A suggested testing equipment design is included. 1.2 This test method does...
April 10, 1998
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
1.1 This test method covers a uniform method for the determination of strain gage fatigue life at ambient temperature. A suggested testing equipment design is included. 1.2 This test method does not...