DSF/PREN 50065-4-3

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz – Part 4-3: Low voltage decoupling filter – Incoming filter

inactive
Organization: DS
Status: inactive
Page Count: 7
scope:

This standard applies to incoming filters used to control the coupling of signals between the utility area and the consumer area. The standard defines: the minimum impedance in the relevant frequency bands at both Utility port and Consumer port, the minimum attenuation of unwanted signals transmitted from the utility side to the consumer side and vice versa. This standard applies to incoming filters designed for single or multiphase installations.

Document History

March 29, 2023
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz – Part 4-3: Low voltage decoupling filter – Incoming filter
This document applies to incoming filters used to control the coupling of signals between the utility area and the consumer area, as illustrated in Figure 1. This document defines: - the minimum...
May 23, 2003
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz – Part 4-3: Low voltage decoupling filter – Incoming filter
This standard applies to incoming filters used to control the coupling of signals between the utility area and the consumer area (see Figure 1). The standard defines: – the minimum impedance in the...
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz – Part 4-3: Low voltage decoupling filter – Incoming filter
This document applies to incoming filters used to control the coupling of signals between the utility area and the consumer area, as illustrated in Figure 1. This document defines: – the minimum...
DSF/PREN 50065-4-3
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz – Part 4-3: Low voltage decoupling filter – Incoming filter
This standard applies to incoming filters used to control the coupling of signals between the utility area and the consumer area. The standard defines: the minimum impedance in the relevant frequency...
Advertisement