DSF/PREN ISO 20776-2

Clinical laboratory testing and in vitro diagnostic test systems – Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test – Part 2: Evaluation of performance of antimicrobial susceptibility test devices against reference broth micro-dilution (ISO/DIS 20776-2:2021)

inactive
Organization: DS
Status: inactive
Page Count: 25
ICS Code (Biological evaluation of medical devices): 11.100.20
scope:

This document establishes acceptable performance criteria for antimicrobial susceptibility test (AST) devices that are used to determine minimum inhibitory concentrations (MIC) of bacteria to antimicrobial agents in medical laboratories. This document specifies requirements for AST devices and procedures for assessing performance of such devices. It defines how a performance evaluation of an AST device is to be conducted. This document has been developed to guide manufacturers in the conduct of performance evaluation studies.

Document History

January 24, 2022
Clinical laboratory testing and in vitro diagnostic test systems – Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices – Part 2: Evaluation of performance of antimicrobial susceptibility test devices against reference broth micro-dilution (ISO 20776-2:2021)
This document establishes acceptable performance criteria for antimicrobial susceptibility test (AST) devices that are used to determine minimum inhibitory concentrations (MIC) of bacteria to...
August 3, 2007
Clinical laboratory testing and in vitro diagnostic test systems – Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices – Part 2: Evaluation of performance of antimicrobial susceptibility test devices
This standard establishes acceptable performance criteria for antimicrobial susceptibility test (AST) devices that are used for determining minimal inhibitory concentrations (MIC) and/or interpretive...
DSF/PREN ISO 20776-2
Clinical laboratory testing and in vitro diagnostic test systems – Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test – Part 2: Evaluation of performance of antimicrobial susceptibility test devices against reference broth micro-dilution (ISO/DIS 20776-2:2021)
This document establishes acceptable performance criteria for antimicrobial susceptibility test (AST) devices that are used to determine minimum inhibitory concentrations (MIC) of bacteria to...