UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

DS/EN IEC 61010-2-091/A11

Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-091: Particular requirements for cabinet X-ray systems

active, Most Current
Organization: DS
Publication Date: 3 May 2021
Status: active
Page Count: 8
ICS Code (Electrical and electronic testing): 19.080
ICS Code (Chemical laboratories. Laboratory equipment): 71.040.10
scope:

1 Scope and object This clause of Part 1 is applicable, except as follows: 1.1 Scope 1.1.1 Equipment included in scope Deletion: Delete the first paragraph. Replacement: Replace the second paragraph (above items a) to c)) with the following new text: This part of IEC 61010 specifies particular safety requirements for cabinet X-ray systems, which fall under any of categories a), b) or c) below. Addition: Add the two following new paragraphs at the end of the subclause: Equipment covered by this document can be both PROTECTED EQUIPMENT or PARTIALLY PROTECTED EQUIPMENT, with X-ray generator voltage up to 500 kV. A cabinet X-ray system is a system that contains an X-ray tube installed in a cabinet, which, independently of existing architectural structures except the floor on which it may be placed, is intended to contain at least that portion of a material being irradiated, provide radiation attenuation and prevent operator access to the radiation beam, during generation of X-radiation. These cabinet X-ray systems are used in industrial, commercial, and public environments, for example, to inspect materials, to analyse materials, and to screen baggage. 1.1.2 Equipment excluded from scope Addition: Add the following new items to the list: aa) Equipment intended to apply X-radiation to humans or animals; bb) Equipment incorporating an X-ray tube but not incorporating complete shielding against X-radiation HAZARDS, such as: - equipment intended to be used within a shielded room which excludes personnel during operation; - equipment intended to be used with separate portable or temporary shielding; - equipment intended to produce an emerging beam of X-radiation. 1.2 Object 1.2.1 Aspects included in scope Addition: Add the following new text to the end of the first paragraph: This part of IEC 61010 specifies requirements for the design and methods of construction of cabinet X-ray systems to provide adequate protection for OPERATORS, ...

Document History

DS/EN IEC 61010-2-091/A11
May 3, 2021
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-091: Particular requirements for cabinet X-ray systems
1 Scope and object This clause of Part 1 is applicable, except as follows: 1.1 Scope 1.1.1 Equipment included in scope Deletion: Delete the first paragraph. Replacement: Replace the second paragraph...
May 3, 2021
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-091: Particular requirements for cabinet X-ray systems
IEC 61010-2-091:2019 specifies particular safety requirements for cabinet X-ray systems, which fall under any of categories a), b) or c) below. a) Electrical test and measurement equipment This is...
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-091: Particular requirements for cabinet X-ray systems
1 Scope and object This clause of Part 1 is applicable, except as follows: 1.1 Scope 1.1.1 Equipment included in scope Deletion: Delete the first paragraph. Replacement: Replace the second paragraph...
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-091: Particular requirements for cabinet X-ray systems
This clause of Part 1 is applicable, except as follows: 1.1 Scope 1.1.1 Equipment included in scope Replacement: Replace the first paragraph with the following new text: This part 2 of IEC 61010...
Advertisement