CSA - CAN/CSA-C22.2 NO. 60601-2-4:12

Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators

inactive
Organization: CSA
Publication Date: 1 January 2012
Status: inactive
Page Count: 183
ICS Code (Anaesthetic, respiratory and reanimation equipment): 11.040.10
scope:

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CARDIAC DEFIBRILLATORS, hereafter referred to as ME EQUIPMENT.

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the general standard.

This particular standard does not apply to implantable defibrillators, remote control DEFIBRILLATORS, external transcutaneous pacemakers, or separate stand-alone cardiac monitors (which are standardized by IEC 60601-2-27 [2]2). Cardiac monitors which use separate ECG monitoring electrodes are not within the scope of this standard unless they are used as the sole basis for AED rhythm recognition detection or beat detection for synchronized cardioversion.

Defibrillation waveform technology is evolving rapidly. Published studies indicate that the effectiveness of waveforms varies. The choice of a particular waveform including waveshape, delivered energy, efficacy, and safety has been specifically excluded from the scope of this standard.

However, due to the critical importance of the therapeutic waveform, comments have been added to the rationale which addresses considerations in waveform selection.

Document History

Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
This Standard applies to ME EQUIPMENT and ME SYSTEMS that are intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I.
January 1, 2019
Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
This Standard applies to ME EQUIPMENT and ME SYSTEMS that are intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I. This International Standard applies to...
Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
This Standard applies to ME EQUIPMENT and ME SYSTEMS that are intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I.
January 1, 2019
Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
This Standard applies to ME EQUIPMENT and ME SYSTEMS that are intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I.
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CARDIAC DEFIBRILLATORS, hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended...
Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CARDIAC DEFIBRILLATORS, hereafter referred to as ME EQUIPMENT. If a clause or subclause is...
CAN/CSA-C22.2 NO. 60601-2-4:12
January 1, 2012
Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CARDIAC DEFIBRILLATORS, hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended...
Medical electrical equipment – Part 2-4: Particular requirements for the safety of cardiac defibrillators
Addition: This Particular Standard specifies requirements for the safety of CARDIAC DEFIBRILLATORS as defined in 2.1.101, hereinafter referred to as EQUIPMENT. This Particular Standard does not...
Medical Electrical Equipment Part 2: Particular Requirements for the Safety of Cardiac Defibrillators and Cardiac Defibrillator-Monitors
A description is not available for this item.
Medical Electrical Equipment Part 2: Particular Requirements for the Safety of Cardiac Defibrillators and Cardiac Defibrillator-Monitors
A description is not available for this item.

References

Advertisement